background image

Gas Conversion

Conversion to LP/Propane Gas

• This range can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory adjusted for use with

NATURAL gas.

• Any conversion required must be performed by your dealer, a qualified licensed technician or gas service

company. Provide the service person with this manual before any work is started on the range. (Gas
conversions are the responsibility of the dealer or end user.)

• The range is supplied with a set of injectors required for converting the range burners.

• Refer to the following table to select the appropriate size injector. The nozzle diameters (hundredths of a

millimetre) are marked on the body of each injector.

• This range can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory

adjusted for use with NATURAL gas.

• Any conversion required must be performed by your dealer, a qualified licensed technician or

gas service company. Provide the service person with this manual before any work is started on
the range. (Gas conversions are the responsibility of the dealer or end user.)

• The range is supplied with a set of injectors required for converting the range burners.

• Refer to the following table to select the appropriate size injector. The nozzle diameters

(hundredths of a millimetre) are marked on the body of each injector.

Setting the Pressure Regulator

The pressure regulator is accessible by removing the storage/warmer drawer; the pressure regulator is positioned on the
rear right side of the range

C.

https://producthelp.fisherpaykel.com/us/Cook/Ranges/Gas/OR36SDG4X1/Installation_Guide_OR36SDG4X1/19_Gas_Conver…

Updated: Wed, 01 Dec 2021 11:49:07 GMT

Powered by

1

Summary of Contents for OR36SDG4X1

Page 1: ...E gas It is shipped from the factory adjusted for use with NATURAL gas Any conversion required must be performed by your dealer a qualified licensed technician or gas service company Provide the servi...

Page 2: ...rage warming drawer while hot Do not remove storage warming drawer during operation Be sure storage warming drawer is empty before removing Always position your hand below the front panel to open clos...

Page 3: ...ners Nominal Power Reduced Power LP Propane 11 279 4mm W C P Natural Gas 4 101 6mm W C P BTU HR BTU HR Injector 1 100 MM Injector 1 100 MM Semirapid SR 7600 LP Propane Gas 1800 78 8000 Natural Gas 180...

Page 4: ...the pan supports the burner caps and the flame spreaders Using a wrench substitute the nozzle injectors with those most suitable for the kind of gas for which it is to be used Refit the flame spreade...

Page 5: ...flame follow these instructions Semi rapid Burner A Light the burner Set the gas valve to LO position minimum rate Remove the dial With a thin screwdriver turn the regulation screw inside the tap rod...

Page 6: ...rown and maximum rate of inner crown Remove the dial With a thin screwdriver turn the regulation screw inside the tap rod until adjustment is correct For LP PROPANE gas tighten the adjustment screws c...

Page 7: ...4 Withdraw the burner as shown 5 Using a 9 32 7mm box spanner unscrew the injector and replace it with a new one selected in accordance with the Injectors table 6 Replace the burner and other compone...

Page 8: ...a 9 32 7mm box spanner unscrew the injector and replace it with a new one selected in accordance with the Injectors table 5 Replace the burner and other components Ensure the safety valve probe V and...

Page 9: ...tes then bring the dial to the lowest temperature setting to operate the thermostat by pass 4 Remove the dial again Taking care not to turn the tap rod slowly screw the by pass screws A until you obta...

Reviews: