517766
March 2003
- 36 -
63.
(00111111) Phase 5 - Pump Comms Error
The Motor Controller module has detected an internal communications problem
between its main control system and the pump control system.
Primary Source:
Motor Controller module.
Action:
Replace Motor Controller module.
64.
(01000000) Phase 5 and 6 - Pressure Transducer (Ptx) error frequency < 66
kHz
The Motor Controller module has received signals from the water level sensor (Ptx)
below normal frequency values.
Primary Source:
Motor controller module.
Action:
Replace Motor Controller module.
65.
(01000001) Phase 5 and 6 - Pressure Transducer (Ptx) error frequency > 90
kHz
The Motor Controller module has received signals from the water level sensor (Ptx)
above normal frequency values.
Primary Source:
Motor Controller module.
Action:
Replace Motor Controller module.
66.
(01000001) Pressure Transducer Error [Ptx Frequency > 90 kHz]
Note:
this supersedes Fault code 65 from V41 Motor controller code onwards.
The Motor Control module has received signals from the water level sensor (Ptx)
above normal frequency values.
Primary Source:
Motor Control module
Action:
Replace Motor Control module
81. - 95. (0101xxxx) Phase 2 to 3 – Display/ Motor Controller. See fault code 106
104.
(01101000) Phase 2 to 6
See fault code 106
105.
(01101001) Phase 2 to 6
Comms Error Time out
These faults are reported when the Display module detects an error in the
communications between the Display module and the Motor Controller.
Note: If the product is an IW the wrong Motor Controller may have been fitted.
Replace with a compatible part.
Primary Source:
Display Module
Action:
Replace Display Module
Secondary Source:
Motor Controller
Action:
Replace Motor Controller
Tertiary Source:
Rotor Position Sensor (Phase 5 and 6)
Action:
Replace Rotor Position Sensor, if this corrects the fault refit the
original Display or Motor Controller.
106. (01101010) Phase 2 to 3 - Display to Motor Controller module
Communications Errors (Phase 6 IW also)
These faults are reported when the Display module detects an error in the
communications between the Display module and the Motor Controller module.
Primary Source:
Display module.
Summary of Contents for ecosmart GWL11