Insufficient Hot Water (Hot Water LED flashing)
This warning is indicated by the hot water LED flashing. Smartdrive will also
be making a rippling set of 5 beeps repeated every 6 seconds. The hot water
is not connected or the water temperature is too low. NB. This warning mode
does not cause the product to PAUSE.
1. Check that the hot water is connected and that the tap is turned on. If
your product is set for 'controlled cold' hot water may still be required for a
cold wash.
2. Check that the water temperature is not too low. The water temperature
may need to be 60oC for a hot wash.
3. Check that the hot water inlet is not connected to the cold water supply.
4. Check that the filter on the hot inlet hose is not blocked.
5. Motor Controller.(Phase 1 to 4). Thermistor (Phase 5).
The temperature sensor has
failed. Replace motor controller.(Phase 1 to 4) Check the resistance of the thermistor.
Resistance is 12.5k ohms at 20oC. Replace if faulty. (Phase 5).
6. Check the size is set correctly.
NB. It is possible to get this warning when washing with cold water if the cold wash
temperature is set at 20oC or more. Wash temperatures may be adjusted, see section
7.1.
16.3.2
Insufficient Cold Water (Cold Water LED flashing)
This warning is indicated by the cold water LED flashing. Smartdrive will also
be making a rippling set of 5 beeps repeated every 6 seconds and the product
will be paused. The cold water is not connected or the flow rate is too low.
1. Check that the cold water is connected and that the tap is turned on.
2. Check that the flow rate is not too low. The product requires a minimum
flow rate of 3 litres per minute. Check that the filter on the cold inlet hose is
not blocked. If the installation has a flow rate below 5 litres per minute the
flow may be improved by using large bore inlet hoses p.n. 426123.
3. Taps may be connected the wrong way round.
4. Cold water temperature exceeds 35oC. NB. Phase 2-4. If cold water
temperature exceeds 40oC high purge motor controllers are available.
Contact your ASC’s.
5.
Phase 1-4
. Motor Controller. The temperature sensor has failed. Replace motor
controller.
6.
Phase 5.
Thermistor.
Check the resistance of the thermistor. Resistance is 12.5k ohms
at 20oC. Replace if faulty.