-33 -
Service Manual
Issue
Rev.
Model No:
DH8060P1
Chapter 10.
Test Programme
To enter diagnostic mode, press and hold Keylock & Dryness Level
for
3
sec. Diagnostic
mode can
be entered while the product is running or from pause/idle state. While in diagnostic mode the keys
and LEDs operate according to the table below.
Function In
Diagnostics
Select
on knob
Then
Press
Description
Test water level
switch
Air Dry
Display “0” = closed
“1” = open
Test Door lock
Air Dry
Display “0” = closed
“1” = open
Test Humidity Sensor Air Dry
The dryer will run for 30 seconds whilst
displaying the humidity value.
After 30s the drum temperature will be
displayed
Run functional self
test (rotate drum,
heating elements,
water pump)
Rack Dry
The dryer will perform the following
sequence and display the numerical code
No output 8888
Motor only CW 7777
Motor only CCW 6666
compressor turns on 5555
(It will be working for 60 seconds to check if the heat
pump system is okay)
Cooling Fan on 5s 4444
Pump run for 5s 3333
Display Test
Turns on all LEDs and shows 8888 in the
display continuously.Press Wrinkle Free
Activate continuous
test mode
Easy Iron
Air Dry
Displa
y “
” for 1 sec.
To turn it off press the Power button off.
To stay in continuous test mode and
run any cycle ‘key lock’ must be
pressed to exit diagnostics mode
Display Information
Everyday
Screen alternates between the display
code selected and the value.
d00 Last user warming
d01 Cycle count of last user warming
d03 Last fault code
d04 Last fault cycle count
d07 Cycle count
d08 Total hrs run
d09
Software version
again to exit back to diagnostics mode.