8
FRONT
ISO
CLEARANCE DIMENSIONS
CG301D
CG451D
CG752D
CG903D
mm
mm
mm
mm
A
Minimum clearance from left edge of cutout to nearest combustible surface
120
60
115
115
B
Minimum clearance from right edge of cutout to nearest combustible surface
120
60
115
115
C
Minimum clearance from rear edge of cutout to:
Nearest combustible surface
Nearest non-combustible surface
85
45
85
45
125
45
125
45
D
Minimum height of non-combustible material when used on adjacent walls
150
150
150
150
E
Minimum clearance from cooktop surface to:
Rangehood
Any other overhead exhaust fan
Downward facing combustible surface
Downwards-facing tiled or fire resistant surface
650
800
650
500
650
800
650
500
650
800
650
500
650
800
650
500
F
Minimum clearance below top of benchtop to:
Combustible surface
Fisher & paykel oven or nearest non-combustible surface
70
65
70
65
70
65
70
65
G
Minimum distance from right edge of cooktop to gas connection point on wall
(if using a flexible hose)
250
250
250
250
H
Distance from floor to gas connection point on wall (if using a flexible hose)
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
min. 800 -
max. 850
I
Maximum overall depth of overhead cabinetry
600
600
600
600
Note: Ensure there is an earthed power outlet within 900 mm of the centre rear of the product. The gas connector on the wall should be 800-850 mm (H) above the floor and to a distance of at least 250 mm (G) outside the width of
the product, on the right-hand side. It should be accessible with the product installed.
5
CLEARANCE DIMENSIONS
A
I
B
C
E
H
D
F
G
A
I
B
C
E
H
D
F
G