478182
8
1.6 Wash
Motor
Electronically commutated 36 pole direct drive 3 phase brushless DC motor.
Motor Resistance @68
o
F (20
o
C): 19.5
Ω
+/- 10% (39
Ω
+/- 1.95
Ω
across any two phases)
1.7 Pump
Motor
The motor is a fully electronically controlled 325V, 3 phase, 6 pole, brushless DC motor.
The speed of the motor will vary depending on whether it is draining or re-circulating the water.
Motor Resistance @68
o
F (20
o
C): 8.1
Ω
+/- 10% per phase (16.2
Ω
+/- 10% across any two phases)
Maximum Wattage:
200W
Nominal Wattage:
60W
Drain Speed:
2500rpm
Recirculation Speed:
2000 rpm
Head Height
Drain Speed
Flow Rate
4ft (Nominal)
2500rpm
6.2 gallons (23.6 litres) per minute
8ft (Maximum)
2500rpm
3.9 gallons (15 litres) per minute
1.8 Water
Valves
Supply
Operation Mode
Voltage
Resistance
Flow Rate
Cold Digitally
Operated
24VDC
64
Ω
@ 68
o
F (20
o
C)
2.6 Gal (10 litres) per min. max
Hot Digitally
Operated
24VDC 64
Ω
@ 68
o
F (20
o
C)
2.6 Gal (10 litres) per min. max
Detergent Digitally
Operated
24VDC 64
Ω
@ 68
o
F (20
o
C)
2.1 Gal (8 litres) per min. max
Fabric Digitally
Operated
24VDC 64
Ω
@ 68
o
F (20
o
C)
.5 Gal (2 litres) per min. max
Bleach Digitally
Operated
24VDC 64
Ω
@ 68
o
F (20
o
C)
.66 Gal (2.5 litres) per min. max
Note: The flow rate will vary slightly depending on pressure.
Water Supply
•
For the best operating conditions the hot water temperature should be approximately 149
˚
F.
•
The hot or cold-water temperature should not exceed 167
˚
F (75
o
C) or 95
˚
F (35
o
C) respectively.
Temperatures above these may cause the machine to fault or cause damage to the machine.
•
If there is an uncontrolled water-heating source (e.g. a wet back or solar heating) a tempering
device should be fitted. This will ensure the hot water temperature remains within safe limits.
For the most suitable type of tempering device we recommend contacting a local plumber or
plumbing supply merchant.
•
Inlet Water Static Pressure 3psi (20kPa) to 150psi (1MPa).
Note: If using a header tank, then the outlet of the header tank must be at least 2 metres
above the top of the clothes washer.
•
The water supply flow rate should be greater than 1.6 gallons (6 litres) per minute (assumes ½
inch diameter pipes).
•
The minimum height of the taps to clear the top of the machine is 45.25 inches (1150mm).
1.9 Thermistor
NTC-type temperature sensor (Thermistor)
Resistance 10,000
Ω
@ 77
o
F (25
o
C)
1.10 Cabinet
Pre-painted steel
1.11 Lid
ABS plastic (co-injected)
1.12 Top
Deck
Polypropylene