160. (10100000) Basket Engaged In Agitate
The bowl has re-engaged itself during agitate.
Primary Source:
Mechanical.
Action:
1) Check that the rotating basket assembly is not jammed to the
agitator with any foreign object that may be caught under the
agitator skirt.
2) Check that the clutch teeth are not locked together with dirt, lint,
etc.
3) Make sure the basket is not overloaded with too many clothes.
4) If none of the above appears to be at fault, then check the air bell
at the bottom of the inner basket for leaks.
Secondary Source:
Installation (drain) set up
Action:
Check that the drain hose is fitted into the drain caddy and extends
no more than ¾” (20 mm) from the end. Check if fitted to a stand pipe
that the drain hose is not pushed down to far.
Tertiary Source:
Motor Control Module.
Action:
If the machine is empty of water at fault, it is possible that the pump
circuit is faulty and has caused a pump out during wash. This would
cause the basket to re-engage during agitate and the Motor Control
Module to display this fault. Replace Motor Control Module.
220. (11011100) EEPROM Model Map Not Programmed
On power up, the Motor Control Module has detected a fault in its memory.
Primary Fault:
Motor Control Module.
Action:
Change Motor Control Module.
230. (11100110) EEPROM Value out of Range
Wrong version detected
Primary Fault:
Motor Control Module is the wrong version.
Action:
Change Motor Control Module.
232. (11101000) COMMS Timeout 5 Sec
IW only problem, either the Display or Motor Control Module has not responded in time.
Primary Fault:
Display Module fault.
Action:
Replace Display Module.
Secondary Fault:
Motor Control Module fault.
Action:
Replace Motor Control Module.
233. (11101001) EEPROM Read Error
Problem in reading the EEPROM data, coming from the Motor Control Module.
Primary Fault:
Motor Control Module fault.
Action:
Replace Motor Control Module.
234. (11101010) Lid Lock Open Circuit.
Check harness to Lid Lock, the connections at the Motor Control Module and lid lock ends.
Primary Fault:
Connectors on the harness at either end could be at fault.
Action:
Replace Harness.
Secondary Source:
Lid lock has failed to be activated.
Action:
Replace Lid Lock Assembly.
Tertiary Source:
Motor Control Module has not responded to the lid lock being
activated.
Action:
Check the lid has a tang and is fitted correctly to activate the lid lock.