background image

Sales and Service Departments 

- all around the world -

GERMANY

HELMUT FISCHER GMBH
Industriestraße 21
D-71069 Sindelfingen

:   +49 (0) 70 31 / 30 3-0

Fax: +49 (0) 70 31 / 30 3-79
[email protected]
www.helmut-fischer.com

GREAT BRITAIN

FISCHER INSTRUMENTATION 
(G.B.) LTD.
Gordleton Industrial Park
Hannah Way · Pennington
GB-Lymington/Hants SO41 8JD

: (+44) 15 90 68 41 00

Fax: (+44) 15 90 68 41 10
[email protected]
www.fischergb.co.uk

USA

FISCHER TECHNOLOGY, INC.
750 Marshall Phelps Road 
Windsor, CT 06095 USA

: (+1) 86 06 83 07 81

Fax: (+1) 86 06 88 84 96
Watts 800 243 84 17
[email protected]
www.fischer-technology.com

SWITZERLAND

HELMUT FISCHER AG
Moosmattstrasse 1 · Postfach · CH-6331 Hünenberg

: (+41) 41 785 08 00 · Fax: (+41) 41 785 08 01

[email protected]
www.helmutfischer.com

Branch Offices of Helmut Fischer AG, Switzerland:

SPAIN

FISCHER INSTRUMENTS, S.A.
C/Almogàvers 157 · 3a Planta
E-08018 Barcelona

: (+34) 93 309 79 16

Fax: (+34) 93 485 05 94
[email protected]
www.helmutfischer.com

ITALY

HELMUT FISCHER S.R.L. 
Tecnica di Misura 
Via Columella 40 · I-20128 Milano

: (+39) 0 22 55 26 26

Fax: (+39) 0 22 57 00 39
[email protected]
www.helmutfischer.com

JAPAN

FISCHER INSTRUMENTS K.K.
Shinmei 1-9-16· Souka-shi
Saitama-ken 340-0012 · Japan

: (+81) 489 29 34 55

Fax: (+81) 489 29 34 51
[email protected]
www.helmutfischer.com

FRANCE

FISCHER INSTRUMENTATION 
ELECTRONIQUE
Parc d'Activités Nord du Pas 
du Lac · 5, rue Michaël Faraday
F-78180 Montigny le Bretonneux
BP 289 · F-78053 St Quentin en 

 

Yvelines Cedex

: (+33) (0) 1 30 58 00 58

Fax: (+33) (0) 1 30 58 89 50
[email protected]
www.helmutfischer.com

HONG KONG

FISCHER INSTRUMENTATION 
(FAR EAST) LTD.
Unit 2901 · Level 29
Metroplaza Tower 2
223 Hing Fong Road
Kwai Chung, N.T.
Hong Kong

: (+852) 24 20 11 00

Fax: (+852) 24 87 02 18
[email protected]
www.helmutfischer.com

THE NETHERLANDS

HELMUT FISCHER 
MEETTECHNIEK B.V.
Tarasconweg 10
NL-5627 GB Eindhoven
Postbus 1828
NL-5602 CA Eindhoven

: (+31) 40 248 22 55

Fax: (+31) 40 242 88 85
[email protected]
www.helmutfischer.com

CHINA

NANTONG FISCHER 
INSTRUMENTATION LTD.
7F, No. 2 Building
2601 Songhuajiang Road
Shanghai 200437 · P.R.C.

: (+86) 21 65 55 74 55 

Fax: (+86) 21 65 55 24 41
[email protected]
www.helmutfischer.com

SINGAPORE

FISCHER INSTRUMENTATION (S) 
PTE LTD.
102 E Pasir Panjang Road #04-04
Citilink Warehouse Complex
Singapore 118529

: (+65) 62 76 67 76

Fax: (+65) 62 76 76 67
[email protected]
www.helmutfischer.com

INDIA

FISCHER MEASUREMENT 

 

TECHNOLOGIES (INDIA) PVT. LTD.
Florida Amenity
S. No. 41, Keshav Nagar
Mundhwa
IN-Pune 411036

: (+91) 20 26 82 20 65

Fax: (+91) 20 26 82 20 75
[email protected]
www.helmutfischer.com

DKD-D-33101

Accredited acc. to

DIN EN ISO/IEC 17025

Valid for Helmut Fischer AG and 
Branch Offices

Summary of Contents for DELTASCOPE FMP10

Page 1: ...DELTASCOPE FMP10 ISOSCOPE FMP10 DUALSCOPE FMP20 Guidelines Coating Thickness Material Testing Microhardness Material Analysis...

Page 2: ......

Page 3: ...Install the batteries rechargeable batteries 7 6 2 Probe connection 8 6 3 Instrument On Off 9 7 Adjusting Instrument and Probe 11 7 1 Assigning a New Probe 11 7 2 Normalization 12 7 3 Corrective Calib...

Page 4: ...tensive oper ator s manual can be found on the CD ROM that is supplied with the instrument The following symbols are used in this brief guide Indicates safety information referring to danger for per s...

Page 5: ...non conducting non magnetic coatings on non ferro magnetic electrically conducting base materials Paint lacquer or plastic coatings on for example aluminum copper zinc etc as well as anodized coating...

Page 6: ...obe connector socket Page 8 2 LCD Display Page 4 3 Keys for directly retrieving functions Page 5 4 USB port for connecting a PC 5 ON OFF key to turn the in strument on or off Page 9 6 Cover additional...

Page 7: ...rement uses the eddy current method Padlock Restricted operating mode is enabled i e the keys ZERO and CAL are not active the service functions cannot be retrieved Arrow circle Free running display is...

Page 8: ...rieves the corrective calibration z Changes the information shown on the LCD display z The display will change faster if is pressed for longer than 3 seconds z Changes the information shown on the LCD...

Page 9: ...easuring beginning on Page 16 z Always hold the probe at its grip sleeve right figure z Always place the probe gently and at a right angle on the specimen surface z Slide the grip sleeve to the specim...

Page 10: ...AM3 MN1500 batteries or 4 individual rechargeable batteries 1 2 V 2400 mAh Type AA Using other batteries may lead to instrument damage Use only non damaged batteries rechargeable batteries If the bat...

Page 11: ...ON OFF key on the right side of the control panel The LCD display is not backlit and no characters are visi ble Protect the instrument and accessories from electrostatic charges Electrical discharges...

Page 12: ...s of the LCD display will appear briefly at the same time Page 4 At the end of the monitoring routine the instrument is ready to make measurements The icon of the measure ment method of the connected...

Page 13: ...e connected NF Fe NC NF Dual probe connected and dual method both set i e in the open application both measurement methods can be used to make measurements NF Fe NC NF Dual probe connected and dual me...

Page 14: ...006 Probe changed The probe must be assigned Chapter 7 1 7 1 Assigning a New Probe Key sequ Action Detail of the LCD display Explanation This warning appears briefly after power up if a probe other th...

Page 15: ...n is per formed s Standard deviation n Number of measurements Base material Fe NF Measurements should be performed on an uncoated spec imen Fe or NF display for the type of base material When using du...

Page 16: ...shed for the calibration curve and stored in the instrument Required materials z Reference part uncoated part from the production z Calibration Standards Selecting the Calibration Standards for the Co...

Page 17: ...f base material will be displayed only after the 1st measurement is completed Perform measurements on the uncoated specimen base material normalization Make measurements at various points of the refer...

Page 18: ...er formed on the calibration standard and then the rated value is corrected using the arrow keys This step is not required if as shown in the example the rated value for the thick ness of the calibrat...

Page 19: ...ration respectively 8 Measuring To make a measurement place the probe at a right angle on the specimen surface The probe can be lifted off after the measurement acquisition i e after the read ing appe...

Page 20: ...ument on After pressing ENTER 5 times the identifi cation number 157 appears on the LCD display 2 x Enter the identification number 159 by pressing the arrow key 2 times Use ENTER to confirm the setti...

Page 21: ...ee running mode Instrument mode Restr Mode Analog display Measurement Audible signal Measurement effect External start Measuring mode Standard Area measurement Automatic measurement Display dual metho...

Page 22: ...29 34 51 japan helmutfischer com www helmutfischer com FRANCE FISCHER INSTRUMENTATION ELECTRONIQUE Parc d Activit s Nord du Pas du Lac 5 rue Micha l Faraday F 78180 Montigny le Bretonneux BP 289 F 78...

Page 23: ......

Reviews: