Installation Instructions
Page 40 Panda PMS AGT-DC 4000 - Chapter D: Installation Instructions
D.2 Generator Connections - Scheme
The generator comes supplied with all supply lines (i.e. electric cables, fuel lines etc.) already
connected to the motor and generator. The supply lines are fed through the capsule's front base
panel and are shielded at the capsule inlets with water-proof grommets.
All electrical connections, cable types and sizes must comply to the appropriate regulati-
ons. The supplied cables are rated for ambient temperatures up to 70°C (160°F). If the
cables are required to meet higher temperature requirements, they must be run through
conduits.
D.2.1 Connections Panda AGT 4000 12V
ATTENTION! Before working on the System read the section “Safety Instructions” on
Page iv.
1
3
4
5
6
7
8
9
10
11
2
11
1.
Passage for battery cable
2.
Passage for battery cable
3.
Raw water inltake
4.
Cable for remote control panel
5.
Cable for VCS
6.
Cable for fuel pump
7.
Cable for voltage sense
8.
Cable for shunt
9.
Connection fuel IN
10. Connection fuel OUT
11. Exhaust OUT
12. Connection external ventilation valvel