![Fischer Panda Panda AGT-DC 4000 PMS Installation Manual Download Page 42](http://html1.mh-extra.com/html/fischer-panda/panda-agt-dc-4000-pms/panda-agt-dc-4000-pms_installation-manual_2294311042.webp)
Generator Failure
Page 36 Panda PMS AGT-DC 4000 - Chapter C: Generator Failure
Checking the fuse on the VCS printed cir-
cuit board.
C.5.2 De-aerating the fuel system
Normally, the fuel system is designed to bleed out air itself i.e. as soon as the electric starter
motor starts operation the fuel pump starts working and the fuel system will be de-aerated after
some time automatically. It is nevertheless essential to bleed the system as follows prior to the
first operation (as all hoses are empty):
1. Put a container under the fuel return pipe to catch running out fuel to catch.
2. Take off the plug at the solenoid of the starter motor.
3. Switch the panel „ON“.
4. Press „START“-button. The fuel pump runs audible.
5. Switch the panel „OFF“.
6. Switch the panel „ON“.
7. Press again the „START“-button.
This procedure must be repeated several times, until fuel (nonporously) withdraws per-
fectly at the fuel return pipe.
8. Switch the panel „OFF“.
9. Attach the plug at the solenoid of the starter motor.