15 

2WR5 LED Icon guide 

 

LED Icon 

  Description 

 

 

 

   Will flash when transmitting to indicating the lock/arm command has been sent 

 

   Will flash + beep confirming the system has been locked/armed 

 

 

   Will flash + beep when transmitting to indicating the unlock/disarm command has been 
sent 

 

   Will flash + beep confirming the system has been unlocked disarmed 

 

 

   Will flash + beep indicating the remote start command has been sent. 

 

   Will flash + beep confirming the system has been remote started/stopped 

 

 

   Will flash + beep when the remote receives an alarm trigger alert 

 
 

 

All 4 icons will flash during remote start to act as a runtime count down timer. Each icon 
represents 25% of the runtime and will stop flashing as timer counts down starting with the 
lock LED. The remote will beep 3 times when 1 minute of runtime left. During the last minute 
of runtime, the remote will beep 1 time/2 seconds 

 

 

 

Remote Start Error Diagnostic 

 
If the remote start fails to start the vehicle, the parking lights will flash three times immediately. 

Following those three flashes the parking lights will flash again corresponding to the error table.  

 

Number of 

Parking Light 

Flashes

 

 

Remote Start Error

 

 

Motor running or must program tach before 1st remote 
start 

Key in ignition on position 

Door open (manual transmission only) 

Foot brake on 

Hood open 

Reservation off (manual transmission only) 

Tach or Tachless sensing failure 

DAS sensor shutdown 

10 

System is in Valet Mode 

2 Way remotes will display the error number “Start Err##” on the LCD. 

 
 

Summary of Contents for CompuSTAR R5 Master

Page 1: ...conditions 1 This device may not cause harmful interference 2 This device may accept any interference received including interference that may cause undesired operation CAUTION Changes or modification...

Page 2: ...s 5 2WR5 User Feature 6 Valet mode options 6 2WT13 Proximity Unlock feature 7 2WR5 Proximity Unlock feature 7 Remote Operation 7 2WT13 Button operation 7 2WT13 Remote Feature table 9 2WT13 LCD Icon de...

Page 3: ...oncerns please contact the original place of purchase For further information you may also contact client services at 888 820 3690 Warranty Coverage Caution The Manufacturer s warranty will be voided...

Page 4: ...button on the Firstech remote The parking lights will flash once to confirm the transmitter has been coded Repeat step 2 for each additional remote up to 4 Note if you only have 2 remotes please progr...

Page 5: ...rging cables are not recommended 2WT13 2WR5 First locate the micro USB port on the top of your remote Connect your micro USB cable to the power adapter and plug into wall outlet The 2WT13 display will...

Page 6: ...can be accessed once you have entered the feature settings The next few pages will discuss these features and how to access activate options found within these features To enter the user feature sett...

Page 7: ...e from the remote enter the user feature settings quick double tap of the center button tap the LOCK or left arrow button until you see the Proximity On feature Tap the center button quick to toggle t...

Page 8: ...AUX2 This will activate any POC assigned AUX 2 output or AUX 2 action over data This function does offer alternative icons within the User feature settings Note Secure AUX mode will affect AUX 1 and...

Page 9: ...is will power on the LCD anytime it is powered off and charged NOTE This remote will ship with the LCD powered off Remote power down Once the power down function is selected within the User feature se...

Page 10: ...timeout 4 sec 8 sec Temperature display F OFF C display brightness low med REMOTE ID remote serial number is displayed when selected high Sound Vibrate low vibrate POWER down powers OFF when selected...

Page 11: ...temperature selected by the install tech at the time of installation This is also a feature that is required to be enabled on the Firstech CM in order for the remote to activate or deactivate it Scre...

Page 12: ...time by activating Valet Mode Once in Valet mode your Firstech system will only control the door locking unlocking function If the remote start is attempted the vehicle should respond with an error 1...

Page 13: ...emote if necessary Once selected the user must then HOLD the center button for at least 8 seconds to completely power the remote off Common LCD ICONS Icon Function Indicates Shock sensor on off X Indi...

Page 14: ...Once a selection is made it will automatically exit the menu Feature Function Description Proximity Unlock Enter feature settings as shown above Tap start start button 1 time to enable disable the pr...

Page 15: ...the runtime and will stop flashing as timer counts down starting with the lock LED The remote will beep 3 times when 1 minute of runtime left During the last minute of runtime the remote will beep 1 t...

Page 16: ...ith the error code After reservation mode failure tap the Start button on 2 Way remotes for second to initiate the shutdown error codes On 1 Way remotes hold the Trunk and Start buttons together for 2...

Page 17: ...iority Situation LED On Duty 2 Door Triggered 2 flashes break then repeat 3 Shock Stage 1 light impact triggered 3 flashes break then repeat 4 Shock Stage 2 Heavy impact triggered 4 flashes break then...

Page 18: ...GES WHATSOEVER INCLUDING BUT NOT LIMITED TO ANY CONSEQUENTIAL DAMAGES INCIDENTAL DAMAGES DAMAGES FOR LOSS OF TIME LOSS OF EARNINGS COMMERCIAL LOSS LOSS OF ECONOMIC OPPORTUNITY AND THE LIKE NOTWITHSTAN...

Reviews: