Operation Manual
FW-1200-M
© 2012
First Water Systems, Inc
pg. 10
4 Post Operation Care
4.1 Flushing System
As soon as possible after an event, flush the system by
pumping clean water for at least 5 minutes.
Remove the Source Water Hose from the source and allow
the system to pump until no water is flowing.
Disconnect all power from the Filtration Unit and Pump.
4.2 Removing Filters
Open Main Valve to relieve pressure on the Canisters.
Unscrew each Canister, using the Filter Wrench where
necessary.
Retain Canister O-Ring.
Remove and discard used Filters.
Drain water from Canisters and dry.
4.3 Cleaning System
Follow instructions above to flush and drain the system.
If sediment remains in the system, replace empty Canisters
and flush with clean water from a garden hose. Note: The UV
Lamp must be powered on for water to flow through.
Follow steps above to remove and dry filter Canisters.
Remove and drain all hoses.
Drain the UV Chamber by opening the Drain Valve located
next to Canister #4, tilt unit slightly to allow water to flow
out of the UV Chamber.