6 Troubleshooting
6.1 Pump will not move water
Check the 120 volt power source
Check the Pump Strainer Basket for debris
Check that the Pump is primed
6.2 Water not flowing from Clean Water Hose
Follow troubleshooting steps for “Pump will not move water”
Check that Main Valve is open
Check power source to Purification Unit
Check Foot Valve for excessive debris
Check the UV Lamp and replace if necessary (The FW-1200-
M will not allow water through the system if the UV Lamp is
not operating)
6.3 Water leaks from top of Canisters
Check that each Canister O-Ring is in place and lubricated
Hand tighten Canister
A small, dripping leak is not abnormal
6.4 Water leaks UV Chamber
Inspect Quartz Sleeve for damage
Inspect Quarts Sleeve O-Rings and Washers (See “Replacing
Quartz Sleeve”)
Tighten UV Canister End Cap