Operation Manual
FW-1200-M
© 2012
First Water Systems, Inc
pg. 6
3.4 Startup
Power
o
Supply 120 volt power to the Pump.
o
Supply 120 volt power to the UV Lamp at the Water
Purification Unit.
o
The Pump has several buttons and lights:
Power Switch: Turns Pump on and off.
Reset Button: Restarts Pump after it has gone
into alarm mode. In some cases, it may be
necessary to disconnect power to reset Pump.
Line Voltage Indicator: Illuminates when
Pump is receiving power.
Pump Operation Indicator: Illuminates when
Pump is operating.
Water Flow Alarm: Illuminates when Pump
stops due to water flow interruption.
Power must be supplied through a Ground Fault Circuit Interrupter
(GFCI) that is properly grounded. If a GFCI circuit is not available,
use the included GFCI Pigtail.
Prime
o
Drop Foot Valve into water source.
o
Fill Source Water Hose with water from open end
opposite Foot Valve.
o
Attach filled Source Water Hose to Pump Inlet.
o
Attach Transfer Hose to Pump Outlet.
o
Open Pump Priming Port and fill with water.
o
Turn Pump on and ensure that water flows at full
pressure.
o
You will need to repeat the Hose/Pump filling
process until a sufficient prime is established.