background image

 

 

STEP 1:

 

Carefully remove all components from packaging.  DO NOT DISCARD PACKAGING until all 
water softener components and fittings have been located. 

STEP 2:

 

Use clips and screws provided and attach bypass valve to the inlet/outlet of the control valve. 
See figure 2 below.   

IMPORTANT:  Mechanical metered (NMS Series) units require the installer to insert the meter cable into 

the top of the meter module. 

 

 

 

 

 

 

 

 

 

 

STEP 3:

 

Place  unit  at  desired  installation  position.   

DO  NOT  plug  into  electrical  outlet  at  this  time 

(see STEP 15 on page 6 or see STEP 10 on page 5).  DO NOT put salt in the brine tank at 
this time (see STEP 14 on page 6). 

STEP 4:

 

Shut off water at main supply.  Relieve pressure by opening nearest faucet.  On private well 
systems,  turn  off  power  to  pump  and  drain  pressure  tank.   

SHUT  OFF  POWER  OR  FUEL 

SUPPLY TO WATER HEATER

STEP 5: 

Cut main supply line as required

 

to fit plumbing to inlet and outlet of bypass valve.  

DO NOT 

PLUMB  INLET  AND  OUTLET  BACKWARDS

.    Piping  should  be  supported.    Do  not  apply 

heat to any fitting attached to the bypass or control valve. 

STEP 6: 

Use polyethylene drain line tubing provided (

NO VINYL TUBING

) to run drain line from control 

valve discharge fitting to floor drain or sump pit capable of handling the backwash rate of the 
softener  (refer  to  specifications  and  flow  rate  on  page  12).   

DISCHARGE  END  OF  THE 

DRAIN  LINE  MUST  BE  FIRMLY  SECURED!   

There  must  be  an  air  gap  at  the  end  of  the 

drain line to prevent siphoning of waste water and meet plumbing code.  Total length of drain 
line should be 

15’ or less.  AVOID OVERHEAD DRAINS.   

FIGURE 2:  Top View of Control Valve 

N, NC, N-HE, & NC-HE 

(Time Clock) 

NMS, NMCS, NMS-HE, & NMCS-HE 

(Mechanical Metered) 

CONTROL VALVE 

METER MODULE 

BYPASS  
IN SERVICE  
POSITION 

OUT 

IN 

RETAINER CLIPS 

DRAIN ELBOW 

ELBOW LOCKNG CLIP 

NECS, NES, NESCC, NES-HE, & INT2 

(Electronic Metered) 

 

Installation Instructions  

Summary of Contents for INT2 Series

Page 1: ...ater Softening Systems Installation Instructions and Owner s Manual MODEL NUMBERS Electronic Metered NECS Series NES Series NESCC Series INT2 Series High Efficiency NECS HE Series NES HE Series MODEL...

Page 2: ...Model Specifications Page 12 Component Parts Breakdown List Page 14 N NC N HE Control Valve Breakdown Page 15 N NC N HE Control Valve Parts List Page 16 NMS NMCS NMS HE Control Valve Breakdown Page 1...

Page 3: ...tral water has a pH of 7 0 lower values indicate acidic water If your pH is below 6 8 you may consider installing an acid neutralizer before the water softener to elevate the pH Iron A naturally occur...

Page 4: ...d to be installed in the line to the water heater in order to allow for thermal expansion and comply with local plumbing codes 4 The water softener should not be subject to freezing temperatures 5 Ens...

Page 5: ...R STEP 5 Cut main supply line as required to fit plumbing to inlet and outlet of bypass valve DO NOT PLUMB INLET AND OUTLET BACKWARDS Piping should be supported Do not apply heat to any fitting attach...

Page 6: ...RAIN LINE TO THE SOFTENER DRAIN LINE STEP 9 Place bypass valve in the Bypass position refer to Figure 4 below Open main supply valve or turn on power to pump on private well systems STEP 10 For all mo...

Page 7: ...trol valve will go to the brine draw position Verify that the water level in the brine tank is dropping Allow water level to drop below the salt grid before continuing If the water level does not drop...

Page 8: ...tener should regenerate If the adjusted hardness falls between two numbers on the chart always use the higher number never round down Example Water Softener Model N 1 3 people in family Adjusted hardn...

Page 9: ...1 2 2 3 3 4 4 5 1 2 3 3 4 6 6 1 2 3 4 6 7 2 3 4 6 6 8 2 3 4 6 9 2 3 6 10 2 3 6 People Adjusted Hardness Grains per Gallon 5 10 15 20 25 30 35 40 45 50 55 60 1 1 1 1 1 1 1 1 1 2 2 2 2 2 1 1 1 1 2 2 2 2...

Page 10: ...part per million Adjusted Hardness 28 gpg 25 3 x 1 0 25 3 28 2 Lift the People Dial on the gallon setting wheel 3 Rotate the People Dial until the number of people in the household is aligned with the...

Page 11: ...e an immediate regeneration cycle 2 Press and release Advance Button during a regeneration cycle to immediately advance the valve to the next step in the regeneration process 3 When the valve is in Pr...

Page 12: ...d Hold the SET Button for 5 seconds NECS NES NESCC NES HE Series Programming Use Up Button to set current hour Use Up Button to set current minute Use Up Button to set AM PM Use Up Button to set ADJUS...

Page 13: ...x 62 APPROXIMATE SHIP WT lbs kg 70 84 77 87 114 145 168 DESCRIPTION UNIT MODEL NUMBER NC 1 S HE N 1 S HE N 1 5 S HE N 2 S HE NMCS 1 S HE NMS 1 S HE NMS 1 5 S HE NMS 2 S HE MEDIA VOLUME ft 3 1 0 1 0 1...

Page 14: ...HE INT2 S MEDIA VOLUME ft 3 liters 1 0 1 3 1 0 1 0 1 5 2 1 0 CAPACITY grains Factory Salt 9 lb ft 3 24 000 32 000 NA NA NA NA 24 000 Factory Salt 6 lb ft 3 NA NA 27 000 27 000 40 500 54 000 NA Max Sa...

Page 15: ...Y BT1234ASSY BT1434ASSY BT1434ASSY BTSQ18ASSY BTSQ1833ASSY Ref Description Units NC 1 S HE NMCS 1 S HE NECS 1 S HE N 1 S HE NMS 1 S HE NES 1 S HE N 1 5 S HE NMS 1 S HE NES 1 5 S HE N 2 S HE NMS 2 S HE...

Page 16: ...15 N NC N HE Time Clock Control Valve Breakdown...

Page 17: ...ank 338 4 10914 1 Injector Throat 1 White NC 1 N 1 N 1 HE N 1 5 N 1 5 HE 10914 2 Injector Throat 2 Blue N 2 N 2 HE 5 10227 Injector Screen 6 10913 1 Injector Nozzle 1 White NC 1 N 1 N 1 HE N 1 5 N 1 5...

Page 18: ...17 NMS NMCS NMS HE Metered Control Valve Breakdown...

Page 19: ...NMCS 1 NMS 1 NMS 1 HE NMS 1 5 NMS 1 5 HE 10914 2 Injector Throat 2 Blue NMS 2 NMS 2 HE 5 10227 Injector Screen 6 10913 1 Injector Nozzle 1 White NMCS 1 NMS 1 NMS 1 HE NMS 1 5 NMS 1 5 HE 10913 2 Injec...

Page 20: ...19 NECS NES NESCC NES HE Metered Control Valve Breakdown...

Page 21: ...81 O Ring Tank 338 5 10914 1 Injector Throat 1 White for NE 1 NEC 1 and NE 1 5 10914 2 Injector Throat 2 Blue for NE 2 6 10227 Injector Screen 7 10913 1 Injector Nozzle 1 White for NE 1 NEC 1 and NE 1...

Page 22: ...in plumbing that is sufficient to be registered by the meter IE running toilet C Eliminate sources of leaks 4 Loss of water pressure A Softener too small for application A Check application requiremen...

Page 23: ...s and as few elbows as possible D Brine valve sticking or leaking soft water D Replace brine valve assembly E Injector or injector screen plugged hard water E Clean or replace injectors and screen F F...

Page 24: ...unction occur contact the dealer that you purchased the product from If you are unable to contact the dealer contact First Sales LLC 260 693 1972 We will require a full description of the problem mode...

Reviews: