12
DESCRIPTION
UNIT MODEL NUMBER
NC-0.75-S
NC-1-S
N-0.75-S
N-1-S
N-1.5-S
N-2-S
N-2.5-S
NMCS-0.75-S
NMCS-1-S
NMS-0.75-S
NMS-1-S
NMS-1.5-S
NMS-2-S
NMS-2.5-S
MEDIA VOLUME, ft
3
0.75
1
0.75
1
1.5
2
2.5
CAPACITY, grains
Factory Salt @ 9 lb/ft
3
18,000
24,000
18,000
24,000
36,000
48,000
60,000
Max. Salt @ 15 lb/ft
3
22,500
30,000
22,500
30,000
45,000
60,000
75,000
SERVICE FLOW RATES, gpm
Continuous (3 gpm/ ft
3
)
2
3
2
3
5
6
8
Service (8 gpm/ ft
3
)
6
8
6
8
10
12
14
Peak*
12
13
12
13
13
14
15
BACKWASH & RAPID RINSE,
gpm
2.4
3.0
1.5
2.4
3.0
4.0
4.0
BRINE FILL,
gpm
0.5
0.5
0.5
0.5
0.5
0.5
0.5
SERVICE PIPE SIZE, inches
¾”
¾”
¾”
¾”
¾”
¾”
¾”
For 1” replace “–S” w/ “-1S” in model #
TOTAL WATER USED
,
gallons
75
87
57
75
87
114
114
DIMENSIONS, inches
Mineral Tank (diameter x height)
10 x 35
10 x 35
8 x 44
9 x 48
10 x 54
12 x 48
13 x 54
Brine Tank (diameter x height)
12 x 34
12 x 34
14 x 34
14 x 34
14 x 34
18 x 33
18 x 33
Overall (depth x width x height)
13 x 22 x 43
13 x 21 x 43
15 x 22 x 52
18 x 27 x 56
18 x 28 x 62
18 x 30 x 56
18 x 32 x 62
APPROXIMATE SHIP WT., lbs (kg)
70
84
77
87
114
145
168
DESCRIPTION
UNIT MODEL NUMBER
NC-1-S-HE
N-1-S-HE
N-1.5-S-HE
N-2-S-HE
NMCS-1-S-HE
NMS-1-S-HE
NMS-1.5-S-HE
NMS-2-S-HE
MEDIA VOLUME, ft
3
1.0
1.0
1.5
2.0
CAPACITY, grains
Factory Salt @ 6 lb/ft
3
27,000
27,000
40,500
54,000
Max. Salt @ 15 lb/ft
3
36,000
36,000
54,000
72,000
SERVICE FLOW RATES, gpm
Continuous (3 gpm/ ft
3
)
3
3
5
6
Service (8 gpm/ ft
3
)
8
8
12
13
Peak*
13
14
14
15
BACKWASH & RAPID RINSE,
gpm
3.0
2.4
3.0
4.0
BRINE FILL,
gpm
0.5
0.5
0.5
0.5
SERVICE PIPE SIZE, in.
¾”
¾”
¾”
¾”
For 1” replace “–S” w/ “-1S” in model #
TOTAL WATER USED
(gallons)
87
75
87
114
DIMENSIONS, inches
Mineral Tank (diameter x height)
10 x 35
9 x 48
10 x 54
12 x 48
Brine Tank (diameter x height)
12 x 34
14 x 34
14 x 34
18 x 33
Overall (depth x width x height)
13 x 23 x 43
18 x 27 x 56
18 x 28 x 62
18 x 30 x 56
APPROXIMATE SHIP WT., lbs
86
86
111
142
GENERAL REQUIREMENTS:
Water Temperature
33°F - 100°F
Water Pressure
25 - 100 psi
Electrical Requirements
110v/60hz
Electrical Current Draw
0.5 amps
NOTES:
*The control valve can handle flow rates greater than the peak flow
rates shown above. What matters is the flow rate the unit can
handle and still provide zero water hardness.
Specifications