01 Activated By:
Zone List
Activated By
0 = delete
1 = zone list
2 = zone type
3 = zone number
[
∗
] to continue
Select where the initiating event for this output definition is to occur
as follows:
0 = delete (deletes the output function and any previous
programming;-see prompt below)
1 = zone list (go to “A” prompt)
2 = zone type (go to “B” prompt)
3 = zone number (go to “C” prompt)
If you enter “0,” the following prompt appears:
Delete?
Press 1 to delete this
0 = NO, 1 = YES
output definition
.
“A”
01 Zn List
1
Zone List
01-08 = zone list
[
∗
] to continue
If zone list was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone list number associated with this output
number.
NOTE: Do not use pager zone lists 09-12 in output definitions.
Press [
✱
] to continue.
Enter the zone list event that will activate this output.
Enter Event
0 = restore; 1 = alarm;
Alarm
1
2 = fault; 3= trouble
NOTE: For alarm, fault, and trouble, an event on ANY zone in the
list activates the output, but ALL zones in the list must be restored
before the output is restored.
Press [
✱
] to continue and skip to the “Output Action” prompt.
“B”
01 Enter Zn type
Perimeter 03
Zone Type
see list at right
If zone type was selected, this screen appears. Otherwise skip to the
next row.
Enter the desired zone type associated with this output number. See
below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used
05 = Trouble Day/Alarm Night 12 = Monitor Zone
01 = Ent/Exit #1
06 = 24 Hr Silent
14 = Carbon Monoxide
02 = Ent/Exit #2
07 = 24 Hr Audible
16 = Fire w/verification
03 = Perimeter
08 = 24 Hr Aux
23 = No Alarm Response
04 = Interior Follower
09 = Fire
24 = Silent Burglary
10 = Interior w/Delay
77 = Keyswitch Zone
81 = AAV Monitor Zone
90-91 = Configurable
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay
36 = **At Bell Timeout***
52 = Kissoff
21 = Arming–Away
38 = Chime
54 = Fire Zone Reset
22 = Disarming
39 = Any Fire Alarm
58 = Duress
31 = End of Exit Time
40 = Bypassing
60 = AAV
32 = Start of Entry Time
41 = **AC Power Failure
66 = Function Key†
33 = Any Burglary Alarm
42 = **System Battery Low
67 = Bell Fail
43 = Comm. Failure
68 = Telco line cut
78 = Keyswitch red LED
79 = Keyswitch green LED
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu Mode to assign the function key (function “07”).
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition
0 = any partition; 1 = partition 1;
Any partition
0
2 = partition 2; 3 = common
Press [
✱
] to continue and skip to the “Output Action” prompt.
Installation Instructions
6-4
Summary of Contents for FA148CP Series
Page 20: ...Installation Instructions 2 14...
Page 48: ...Installation Instructions 5 8...
Page 54: ...Installation Instructions 6 6...
Page 58: ...Installation Instructions 8 2...
Page 68: ...11 4...
Page 76: ...Installation Instructions 13 4...
Page 81: ...NOTES 14 5...
Page 82: ...NOTES Installation Instructions 14 6...
Page 83: ...NOTES 14 7...
Page 84: ...NOTES Installation Instructions 14 8...
Page 85: ...NOTES 14 9...
Page 86: ...NOTES Installation Instructions 14 10...
Page 87: ...NOTES 14 11...