background image

Firetide Instant Mesh Networks

 25

 

Appendix D - Regulatory Notices

USA 

FCC Class A Notice 

This device complies with Part 15 of the FCC Rules. Operation is sub-
ject to the following two conditions: 

This device may not cause harmful interference. 

• 

This device must accept any interference received, including in-

• 

terference that may cause undesired operation. 

FCC Part 15 Note 

This equipment has been tested and found to comply with the limits 
for a Class A digital device, pursuant to Part 15 of the FCC Rules. 
These limits are designed to provide reasonable protection against 
harmful interference in an office installation. This equipment gen-
erates,  uses  and  can  radiate  radio  frequency  energy  and,  if  not 
installed and used in accordance with the instructions, may cause 
harmful interference to radio communications. However, there is no 
guarantee that interference will not occur in a particular installa-
tion. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equip-
ment off and on, the user is encouraged to try to correct the inter-
ference by one or more of the following measures: 

Reorient or relocate the receiving antenna. 

• 

Increase the separation between the equipment and receiver. 

• 

Connect the equipment into an outlet on a circuit different from 

• 

that to which the receiver is connected. 
Consult the dealer or an experienced radio/television technician 

• 

for help. 

FCC Part 90 Note 

This  equipment  has  been  tested  pursuant  to  FCC  Part  90,  DSRC-C 
mask certification, and is approved for use in the US on Public Safety 
bands by licensed Public Safety agencies. 

Public Safety Band 

Pursuant to Part 90.1215, use of antennas with gain greater than 9 
dBi and up to 26 dBi in the 4.940 - 4.990 GHz Public Safety band is 
permissible without reduction of TX output power. The antenna shall 
have a directional gain pattern in order to meet the requirement of 
point to point and point to multi-point operation. 

Modifications 

Any  modifications  made  to  this  device  that  are  not  approved  by 
Firetide, Inc. may void the authority granted to the user by the FCC 
to operate this equipment. 

FCC Radiation Exposure Statement 

To ensure compliance with the FCC’s RF exposure limits, the antenna 
used for this transmitter must be installed to provide a separation 
distance of at least 90 cm from all persons and must not be co-lo-
cated or operated in conjunction with any other antenna or trans-
mitter. Installers and end users must follow these installation in-
structions. 

Installation 

Antenna(s) for this unit must be installed by a qualified profession-
al. Operation of the unit with non- approved antennas is a violation 
of U.S. FCC Rules, Part 15.203(c), Code of Federal Regulations, Title 
47. 

Canadian Compliance Statement 

This Class A Digital apparatus meets all the requirements of the Ca-
nadian  Interference-Causing  Equipment  Regulations.  Cet  appareil 
numerique de la classe A respecte les exigences du Reglement sur 
le material broilleur du Canada. This device complies with Class A 
Limits of Industry Canada. Operation is subject to the following two 
conditions: 
1. This device may not cause harmful interference, and 
2. This device must accept any interference received, including in-
terference that may cause undesired operation. 
Firetide HotPoint 6100 and 6200 wireless mesh nodes are certified 
to the requirements of RSS-210 for 2.4 and 5 GHz spread spectrum 
devices. The use of this device in a system operating either partially 
or completely outdoors may require the user to obtain a license for 
the system according to the Canadian regulations. For further infor-
mation, contact your local Industry Canada office.

January 2009

Summary of Contents for HotPort 6101

Page 1: ...Guide are subject to change without notice Please refer to the Firetide partners web site partners firetide com for current versions Hardware Installation Guide HotPort Series 6000 Indoor and Outdoor...

Page 2: ...rmance interruption or failure of the product irrespective of the cause of action even if Firetide has been advised of the possibility of such damages Firetide s cumulative liability for all claims ar...

Page 3: ...2 Mounting the Node 13 Connecting Cables 14 Power Connection 14 Connecting Ethernet Cables 15 Building a Custom Ethernet Cable 15 Typical Connections 16 Adding a HotPoint AP to a HotPort Node 17 Appen...

Page 4: ...cident happens Don t attempt repair work when you are tired Not only will you be more careless but your primary diagnostic tool deductive reasoning will not be operating at full capacity Use approved...

Page 5: ...nas Two detachable 2 4 GHz omnidirectional antennas Two detachable 5 GHz omnidirectional antennas Power External power module with NEMA5 15 US to IEC 320 cord Other IEC cords are available separately...

Page 6: ...202 Kit Left showing weatherproof Ethernet kit Right showing hardware kit Figure 3 6202 Node as packed showing mounting plates HotPort Node CD AC Power Brick Hardware Kit Antennas Quick Install Warran...

Page 7: ...easy to install They are mechanically compatible with existing HotPort nodes Series 6000 nodes form their own mesh and can connect to Series 3000 meshes via Mesh Bridge A Series 6000 node can also be...

Page 8: ...na a minimum of 1 meter 3 ft apart A separation of 1 6 m 5 ft is preferred This usually provides sufficient isolation to avoid overload problems If this is not possible you must select and place the a...

Page 9: ...ted to a pole or other se cure structure The antennas should not be within 1 meter 3 ft of any metal bar or structure and ideally not within 1 meter 3 ft of any concrete or stone structure In general...

Page 10: ...he reset button in the lower right corner of the rear panel To reset the unit apply power and wait until the unit has fully booted and the status light has come on Then use a paperclip to press and ho...

Page 11: ...e more than 10 ohms Understanding the soil is very important in order to create a proper earth ground If your soil is rocky or sandy drive your ground rods and then pull them back out and dump an appr...

Page 12: ...ortable stand until you can determine the ideal location for permanent mounting The location must allow for a solid connection to earth ground Be sure the ground does not obstruct access to the enclos...

Page 13: ...nt Using Mounting Straps For poles with diameters larger than 50 mm 2 irregularly shaped poles or light poles you can use mounting straps not supplied to mount the HotPort enclosure Position the unive...

Page 14: ...to the bracket so that the four tabs on the node assembly engage the straps on the bracket as shown in Figure 20 Figure 20 Mounting the Node Vertical Mast Figure 21 Mounting the Node Horizontal Pole T...

Page 15: ...Port node If you wish to power your node with DC power you will need a source of power which can deliver 15 V 10 at 3 A Information on building custom power cables is shown in Appendix B Do not connec...

Page 16: ...if used out doors To assist in cable construction Firetide supplies a weatherized Eth ernet transition cable It is PoE compatible A weatherized RJ 45 coupler is also included To use the transition cab...

Page 17: ...a close up of a MAC address label is shown in Figure 30 Typical Connections Figure 30 MAC Address Label Once you have completed the installation and verified that the sys tem works correctly you must...

Page 18: ...to appoximately 50 N m 36 ft lbs as shown in Figure 32 Do not overtighten these bolts thread into aluminum Figure 32 AP Bolted to HotPort Next re attach the backing plate to the body of the AP as show...

Page 19: ...On the right the assembly complete with all antennas has been attached to a horizontal bar which is then bolted to the mast Figure 35 HotPoint HotPort Assembly Vertical and Horizontal Mounts Once you...

Page 20: ...nical support from Firetide Simply email Product Returns Please contact your Firetide dealer for instructions on returning defective or damaged products for repair or replacement Do not return product...

Page 21: ...10 BaseT 100 BaseTX 2 TXD TX Data 10 BaseT 100 BaseTX 3 RXD RX Data 10 BaseT 100 BaseTX 4 PoE 48 VDC PoE Power 5 PoE 48 VDC PoE Power 6 RXD RX Data 10 BaseT 100BaseTX 7 PoE 48 VDC PoE Power 8 PoE 48...

Page 22: ...ble Wiring brown blue black white positive lead power nominal 15 volts ground drain Pin 1 Pin 2 Pin 3 Pin 4 4 pin LTZ Connector Series 6200 DC Power Connector 5 6 1 2 3 ground 4 power Cable End View D...

Page 23: ...802 11b 24 dBm all rates 802 11g 26dBm 6 24Mbps 26dBm 36Mbps 25dBm 48Mbps 24dBm 54Mbps Supported Data Rates Standards 802 11a 6 9 12 18 24 36 48 54Mbps 802 11a Capable of switching to 1 4 and 1 2 rate...

Page 24: ...ting External power cord Removable sun shield One weatherized Ethernet transition cable with watertight RJ 45 coupling Additional cable kits may be ordered Staging antennas 1 pair Optional Accessories...

Page 25: ...he 4 940 4 990 GHz Public Safety band is permissible without reduction of TX output power The antenna shall have a directional gain pattern in order to meet the requirement of point to point and point...

Page 26: ...ing HotView mesh management software Step 2 Tightly wrap a layer of electrical tape STICKY SIDE OUT over the connector from base of unit to one inch over the cable When wrap ping the tape should overl...

Page 27: ...ressor connection Step 6 Using plenty of tension tightly wrap a layer of butyl rubber splicing mastic tape over the electrical tape Overlapping the tape about 40 on each turn start from base of unit a...

Page 28: ...Firetide Inc 16795 Lark Avenue Suite 200 Los Gatos CA 95032...

Reviews: