Appendix B - Connector Wiring
HotPort Outdoor Node Ethernet Transition Cable Pin Descriptions
Table 2. Circular, Watertight IP66-Rated Connector and Port Pin Descriptions
Connector Pin #
Wire Color
Port Pin #
1
White/Orange
1
9 10
7 8
5 6
3 4
1 2
2
Orange
2
3
White/Green
3
4
Blue
4
5
White/Blue
5
6
Green
6
7
White/Brown
7
8
Brown
8
Drain Wire
9
Drain Wire
10
Table 3. RJ-45 Connector Pin Descriptions
Pin #
Signal
Description
1
TXD+
TX Data 10 BaseT/100 BaseTX
2
TXD-
TX Data 10 BaseT/100 BaseTX
3
RXD+
RX Data 10 BaseT/100 BaseTX
4
PoE+
+48 VDC PoE Power
5
PoE+
+48 VDC PoE Power
6
RXD-
RX Data 10 BaseT/100BaseTX
7
PoE-
-48 VDC PoE Power
8
PoE-
-48 VDC PoE Power
HotPort Outdoor Node AC Power Connector
Figure 36 shows the pinout of the AC Power connector used on Series 6200 outdoor nodes. Views are shown of both the connector on the
unit, and the mating connector on the cable itself. Pin 1 is neutral; pin 2 is line, and pin 3 is ground.
Figure 36. Series 6200 AC Power Connector
1-neutral
2-line
3-ground
Series 6200 AC Power
Cable-End View
1-neutral 2-line
3-ground
Series 6200 AC Power
Connector View