background image

28

FLKV12

For use with any burner up to 120K BTU’s. Kit Includes: (1) 36” L x ½” Diameter Flex Line + ½” Key Valve + 4” and 12” Key

FLKV34

For use with any 121K - 249K BTU Burner. Kit Includes: (1) 36” L x 3/4” Diameter Flex Line + 3/4” Key Valve + 4” and 12” Key

FLKV34FIT180

For use with any 121K - 249K BTU Burner. Kit Includes: (1) 36” L x 3/4” Diameter Flex Line + 3/4” Key Valve + 4” and 12” Key + ½” x 2” Nipple to connect threaded 

inside 3/4” Flex Line Flare Connector to ½” Plate Coupling

DFLKV34

For use with any burner over 249K BTU’s. Kit Includes: (2) 36” L x 3/4” Diameter Flex Lines with + 3/4” Key Valve + 4” and 12” Key

DFLKV34FIT250

For use with any burner over 249K BTU’s. Kit Includes: (2) 36” L x 3/4” Diameter Flex Lines + 3/4” Key Valve + 4” and 12” Key + (1) 3/4” x ½” MM Reducer Fitting and (1) 

3/4” Tee for connection at ½” Plate Co (1) 3/4” x 3” Nipple and (1) 3/4” Tee for Key Valve connection

DFLKV34FIT300

For use with any 300K+ BTU Burner. Kit Includes: (2) 36” L x 3/4” Diameter Flex Lines + 3/4” Key Valve + 4” and 12” Key + (1) 3/4” x 3” Nipple and (1) 3/4” Tee for 

connection at 3/4” Plate Co (1) 3/4” Tee for Key Valve connection

FIT180

Flex Line & Key Valve Connection Fitting for use with any burner over 249K BTU’s. Kit includes: (1) ½” x 2” Nipple. Connects ½” Plate Coupling to inside threaded 3/4” 

Flex Line Flare Connector

FIT250

Flex Line & Key Valve Connection Fittings for 250K - 299K BTU Burner. Kit includes: (1) 3/4” x ½” MM Reducer Fitting and (1) 3/4” Tee for connection at ½” Plate 

Co (1) 3/4” x 3” Nipple and (1) 3/4” Tee for Key Valve connection. Connects ½” Plate Coupling to two 3/4” Flex Lines + connection of two 3/4” Flex Lines to 3/4” 

Key Valve.

FIT300

Flex Line & Key Valve Connection Fittings for 300k+ BTU Burner. Kit includes: (1) 3/4” x 3” Nipple and (1) 3/4” Tee for connection at 3/4” Plate Co (1) 3/4” x 3” 

Nipple and (1) 3/4” Tee for Key Valve connection. Connects 3/4” Plate Coupling to two 3/4” Flex Lines and two 3/4” Flex Lines to 3/4” Key Valve.

FL3612

36” L x ½” Diameter Flex Line (MM)

KV12

½” Key Valve + 4” Key

KEY12

12” Key

DRIPLEG12

½” Drip Leg Kit

LPRH

LP Regulator mounted on 3/8” 10’ Hose with handwheel quick connect. For use up to 125k BTU’s. For Use with a 20LB propane tank

LPHOSE10

LP 3/8” 10’ Hose. For use with a 20LB Propane Tank

REGLPNG125

½” FNPT Inlet x ½” FNPT Outlet. LP/NG convertible. Up to 125K BTU’s

REGLPNG140

1/4” FNPT Inlet x 3/8” FNPT Outlet. LP/NG convertible. Up to 140K BTU’s

FL3634

36” L x 3/4” Diameter Flex Line  (MM)

KV34

3/4” Key Valve + 4” Key

KEY24

24” Key

DRIPLEG34

3/4” Drip Leg Kit

Replacement Parts

Ignition Systems

PBIK 

Push Button Ignition Kit: spark igniter rod and wire + push button battery operated control module

PB-SI

Spark igniter rod and wire

PB-CM

Push button battery operated control module

PBMBR

Mounting Bracket

3VIK-NG / 3VIK-LP

Full Replacement Kit for 3V Ignition System

3VCM 

3V Control Module 

3VPA-NG / 3VPA-LP

3V Pilot Assembly (pilot tube + i spark wire + igniter b wind cage)

3VGV-NG / 3VGV-LP

3V 120K BTU Capacity Gas Valve

Battery Pack

3V Battery Pack

3VSTEP

3V Step Down Transformer

24VIKSC-NG / 24VIKSC-LP

Full Replacement Kit for Standard 24V Ignition System (Standard Capacity)

24VGVSC-NG / 24VGVSC-LP

24V 200K BTU Capacity Gas Valve (Standard Capacity)

24VIKHC-NG / 24VIKHC-LP

Full Replacement Kit for Standard 24V Ignition System (High Capacity)

24VGVHC-NG / 24VGVHC-LP

24V 400K BTU Capacity Gas Valve (High Capacity)

24VCM 

24V Control Module for use with Standard Ignition Systems (SC & HC)

24VPA-NG / 24VPA-LP

24V Pilot Assembly (pilot tube + i spark wire + igniter b wind cage) for use with Standard Ignition Systems (SC & HC)

Transformer

For use with all 24V Ignition Systems (Standard Ignition and Premium Ignition)

P24VIKSC-NG / P24VIKSC-LP

Full Replacement Kit for Premium 24V Ignition System (Standard Capacity)

P24VCBSC

Premium 24V 290K BTU Capacity Control Box (Standard Capacity)

P24VIKHC-NG / P24VIKHC-LP

Full Replacement Kit for Premium 24V Ignition System (High Capacity)

P24VCBHC

Premium 24V 512K BTU Capacity Control Box  (High Capacity)

P24VIKPA-NG / P24VIKPA-LP

Premium 24V Pilot Assembly (pilot tube + i spark wire + igniter b wind cage) for use with Premium Ignition Systems (SC & HC)

P24VIKWC

Wind Cage

www.

FiresideXpressions

.com  |  

1.888.986.1535

 |  

support

@

firesidexpressions

.com

Summary of Contents for CFB120

Page 1: ...1 B R A S S B U R N E R S Installation Manual Crossfire Brass Burners www firesidexpressions com 1 888 986 1535 support firesidexpressions com...

Page 2: ...on Premium Ignition Model CFB180LP with Premium 24 Volt electronic ignition system Model CFB180NG with Premium 24 Volt electronic ignition system Model CFB290LP with Premium 24 Volt electronic ignitio...

Page 3: ...24 Volt standard capacity electronic ignition system Model CFB120LP P24VIKSC CFB120LP plate or pan lava rock Premium 24 Volt standard capacity electronic ignition system Model CFB120NG P24VIKSC CFB120...

Page 4: ...by the authority having jurisdiction in gas piping WARNING We suggest that our products be serviced annually by a licensed plumber WARNING It is the installer s responsibility to follow installation i...

Page 5: ...ly joint compound thread sealant or tape to all male pipe fittings only and DO NOT use on FLARED fittings Be sure to tighten every joint securely WARNING To prevent damage to burner unhook fire featur...

Page 6: ...ttle tank to CLOSED position 4 After allowing for amply cooling time cover the fire feature with water proof weather proof cover LIGHTING INSTRUCTIONS FOR 3V Battery Operated System 24V Premium Electr...

Page 7: ...f pilotgasorificemayberequiredby removing pilot hood CCW andremovingorificeandcleaningoutorificesfromdebris soot or anythingthatmaybepreventinggoodgasflow fromexitingthepilot gasorifice PushButtonOnly...

Page 8: ...recommends a 4 clearance from the finished top of your fire pit capstones to your plate For Match Lit burners Warming Trends TM recommends a minimum 6 clearance below plate for additional connections...

Page 9: ...t here Plate Coupling Flared Fitting STEP 3D STEP 3D PREMIUM 24 VOLT IGNITION Coupling Flared Fitting Premium 24 Volt Ignition Drip Leg Plate Apply thread sealant here STEP 3C STEP 3C STANDARD 24 VOLT...

Page 10: ...o the fitting now located on the bottom of your aluminum plate Coupling Flex Line Flared Fitting STEP 4B 3 VOLT IGNITION STEP 4b Coupling Flex Line Plate Flared Fitting 3 Volt Ignition Drip Leg STEP 4...

Page 11: ...n into transformer FINAL SET UP STEP 6B 3 VOLT IGNITION Drip Leg Coupling 3 Volt Gas Valve Flex Line Plate Flared Fittings Key Valve Key In Gas Line In STEP 6C STANDARD 24 VOLT IGNITION Drip Leg Coupl...

Page 12: ...uctions STEP 3 STEP 3 Connect your FIT180 fitting to the inside threads of one of the 3 4 flared fittings removed in Step 3 Apply thread sealant here 1 2 x 2 Nipple FIT180 3 4 Flare Fitting Use inside...

Page 13: ...EP 4D Apply thread sealant here Coupling Premium 24 Volt Ignition Drip Leg Flared Fitting Plate 1 2 x 2 Nipple FIT180 1 2 x 2 Nipple FIT180 STEP 5A MATCH LIT SYSTEM Connect 3 4 flex line to the fittin...

Page 14: ...ing Plate Key Valve Flared Fitting Gas In Key In STEP 7B STANDARD 24 VOLT IGNITION Coupling Key Valve Plate Standard 24 Volt Ignition Drip Leg Gas Line In Key In Flex Line Flared Fittings 1 2 x 2 Nipp...

Page 15: ...the FIT300 Turn to page 20 for installation instructions FOR PUSH BUTTON IGNITION INSTRUCTIONS Follow Match Lit System installation instructions When finished turn to page 25 for Push Button Ignition...

Page 16: ...STANDARD 24 VOLT HIGH CAPACITY IGNITION SEE PAGE 20 FOR INSTALLATION INSTRUCTION STEP 3c STEP 3C PREMIUM 24 VOLT STANDARD CAPACITY IGNITION Coupling Apply thread sealant here Drip Leg Plate Premium 2...

Page 17: ...4 Tee FIT250 Plate Plate STEP 4A Connect one 3 4 tee fitting to the connection made in Step 3 1 2 x 3 4 reducing fitting to the 1 2 coupling under aluminum pan STEP 4 Apply thread sealant here 3 4 Tee...

Page 18: ...IUM 24 VOLT IGNITION Same as above Flared Fitting Flared Fitting Apply thread sealant here Apply thread sealant here 3 x 3 4 Pipe Nipple FIT250 Key Valve 3 4 Tee FIT250 STEP 8 Connect remaining 3 4 te...

Page 19: ...lex Line Key Valve Key In Gas In STEP 11 STANDARD 24 VOLT AND PREMIUM 24 VOLT IGNITION SYSTEMS ONLY Plug ignition into three prong above grade NEMA Rated outdoor specific GFCI electrical outlet or hav...

Page 20: ...STEP 1 FIT250 STEP 1 FIT250 FIT300 2 3 4 x 3 Nipples 2 3 4 Tees STEP 1 Locate DFLKV34 and FIT300 Parts include two 3 4 flex lines key valve and keys 4 and 12 plus FIT300 Kit 4 Key 12 Key Key Valve Pre...

Page 21: ...FIT300 STEP 3B STANDARD 24 VOLT IGNITION STEP 3C PREMIUM 24 VOLT IGNITION Coupling Coupling Plate Plate Drip Leg Drip Leg 3 4 x 3 Nipple FIT300 3 4 x 3 Nipple FIT300 Apply thread sealant here Apply t...

Page 22: ...ion Plate STEP 5C PREMIUM 24 VOLT IGNITION STEP 5c Coupling 3 4 Tee FIT300 3 4 x 3 Nipple FIT300 Flared Fitting Flared Fitting Premium 24 Volt Ignition Drip Leg Plate Apply thread sealant here Apply t...

Page 23: ...thread sealant here Flared Fitting Flared Fitting 300K BTU Systems with DFLKV34 and DFLKV34FIT300 STEP 6A Connect both 3 4 flex lines to the 3 4 flared fittings connected in Step 5 Tighten with cresce...

Page 24: ...MA Rated outdoor specific GFCI electrical outlet or have electrician hardwire ignition into transformer FINAL SET UP Coupling Flared Fitting Flared Fitting Flared Fitting Flared Fitting Flex Line Flex...

Page 25: ...5 away from the inside edge of the jet NOTE If Spark Igniter is too high when flush with plate run mechanism up through bottom of plate 125 125 STEP 1 To place Spark Igniter in proper position the ins...

Page 26: ...unting Bracket Push Button Module Spark Igniter Wires Key Valve Push Button Ignition Key Valve Push Button Module Washer 1 Washer 2 Nut Button Cover AAA Battery STEP 4 Install push button module into...

Page 27: ...r KV34 12 Key KEY12 Key Valve KV12 or KV34 Pressure Face Plate KV12 or KV34 Flex Line FL3612 or FL3634 Flared Fitting Flared Fitting Parts Glossary Spark Igniter PB SI Push Button Module PB CM Mountin...

Page 28: ...2 Drip Leg Kit LPRH LP Regulator mounted on 3 8 10 Hose with handwheel quick connect For use up to 125k BTU s For Use with a 20LB propane tank LPHOSE10 LP 3 8 10 Hose For use with a 20LB PropaneTank...

Reviews: