![FireplaceXtrordinair 36DV-A/R Owner'S Manual Download Page 28](http://html1.mh-extra.com/html/fireplacextrordinair/36dv-a-r/36dv-a-r_owners-manual_2291983028.webp)
P
AGE
28
O
PERATION
Before You Begin
!
Read this entire manual before you use your new fireplace (especially the section "Safety
Precautions" on pages 2 & 3). Failure to follow the instructions may result in property
damage, bodily injury, or even death.
Location of Controls - See explanation below
T
O
L
P
I
ON
OFF
Open the access door
to view the controls.
Gas
Control
Valve
PILOT ADJ
VENT
T
O
L
PI
ON
OFF
HI
LO
Gas Control Knob
Flame Adjust Knob
An instruction card for operating
the fireplace is attached to the
inside of the fireplace here.
Replace it for easy reference.
The pilot flame is located
below the back log.
ON
OFF
MAIN BURNER
On/Off Switch
PILOT
IGNITER
Pilot Igniter
BLOWER
CONTROL
LO
OFF
Blower Knob
HI
LO
OFF
HI
Blower Knob
This knob controls the speed of the internal convection blower that pushes the
heated air into the room.
On/Off Switch
This control is used to turn the fireplace on and off.
Pilot Igniter
The pilot igniter is used only to start the pilot. When pressed, it sends an
electrical charge to the pilot assembly. This creates a blue spark directly next
to the pilot, igniting the pilot flame.
Gas Control Knob
This knob is used to control gas to the fireplace and for starting the pilot.
There are three positions, ON, OFF, & PILOT. The pointer directly below the
knob indicates the position this knob is in.
Flame Adjust Knob
This knob controls the flame height from low ("LO") to high ("HI"). The
pointer to the upper left of the knob points to the position this knob is in.
?
If using a remote control or thermostat, the On/Off Switch must be left "ON". Turning the On/Off
Switch "OFF" will keep the fireplace off always.