![FireplaceXtrordinair 36 ELITE-ZC Installation Manual Download Page 9](http://html1.mh-extra.com/html/fireplacextrordinair/36-elite-zc/36-elite-zc_installation-manual_2291979009.webp)
I
NSTALLATION
(C
ONTINUED
)
P
AGE
9
Mantel Requirements
•
The optional mantel must be a minimum 23" above the top of the faceplate (57-1/2" above the base)
•
The mantel must not extend more than 8-1/2" in front of the faceplate.
•
Mantel side columns that protrude more than 3/4" must maintain an 18" clearance to the faceplate
•
Collinswood® makes a mantel specifically designed for the Fireplace Xtrordinair 36 Elite-ZC. This
mantel has been listed with this appliance as a component of this appliance and is not subject to the
above mantel requirements. NOTE: do not cut the mantel to reduce its clearance to the fireplace -
the base of the mantel must be at the same height as the base of the fireplace. The above
requirements apply to all other site-built or pre-manufactured mantels.
Hearth Requirements
?
Local building codes may require a
minimum hearth requirement different
of what this manual states
•
Hearth must extend 20" in front of the
faceplate when it is not elevated (see
local building codes). Hearths raised 6-
1/2" must extend a minimum 18".
•
Hearth must extend a minimum 8" to
both sides of the faceplate (52" wide)
•
Hearth must be a minimum 1" thick of
cement board (or equivalent)
•
Hearth must not rise more than 6-1/2"
above the base of the fireplace
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
AAAAAA
23"
Mantel (may be
combustible)
Minimum
Mantel
Clearance
20" (18" in
some cases)
Minimum
Hearth
Width = 52"
8" Min.
57-1/2"
AAAAAA
AAAAAA
AAAAAAAAA
AAAAAAAAA
Combustible
Floor
No hearth material can
go above this point
Fireplace
Faceplate
Ember
Strip
6 1/2"
Max.
18" Min.
(Check Local Building Codes)
AA
AA
AA
AAAAAAAAA
AAAAAAAAA
A
A
A
A
AAAAAAAAA
AAAAAAAAA
AA
AA
AA
Minimum 1" cement board
Fireplace
Ember
Strip
2 x 4 Framing
No combustible material
permitted above this point
15"
Raised
hearth
3/4"
Plywood
AAAAAAAAA
AAAAAAAAA
A
A
A
Fireplace
2 x 8 Framing
Faceplate
Ember
Strip
15"
Raised
hearth
Elevated hearths must be
constructed of non-combustible
materials such as cement blocks
(6-1/2” Max.).
20" Min.
(Check Local Building Codes)
Tile or
marble
Fireplace
A
A
A
A
Faceplate
Combustible Floor
Ember
Strip
Header height needs to be
increased this dimension.
Header height will
need to be increased
this dimension.
Min. 1" cement board
(or equivalent)
Tile or
marble
3/4"
Plywood
Tile or
marble
Summary of Contents for 36 ELITE-ZC