background image

11

OPERATION – UNITS WITH

GAS CONTROL VALVE continued

FIGURE 21 – PILOT ASSEMBLY

FIGURE 22

LIGHTING INSTRUCTIONS

UNITS WITH SAFETY PILOT

1-

STOP!

Read all warnings and safety information in this

manual.

2-

WARNING:

BE SURE THAT THE CHIMNEY DAMPER

IS FULLY OPEN!

LIGHTING THE PILOT

3-

Push in the gas control knob slightly, and turn it in a
clockwise direction to the OFF position. DO NOT FORCE!
NEVER USE ANY TOOL, TO ROTATE THE GAS
CONTROL KNOB! If gas control knob will not rotate,
contact your installer or the

fire

gear Service Center.

( SEE FIGURE 22 & 23 )

FIGURE 23

4-

Slowly, turn on the gas, at the manual shut-off valve,
beside the fireplace.

5-

STOP! WAIT FIVE ( 5 ) MINUTES!

6-

If you smell gas,

STOP!

7-

Turn off the gas at the manual shut-off valve, and recheck
all gas connections for leaks. Do not continue until all
leaks are corrected. Once you are assured that there are
no leaks, proceed with step eight ( 8 ).

8-

Locate the pilot. Pilot is located at the rear, right-hand
side of the unit.
( SEE FIGURE 20 & 21 )

FIGURE 24

9-

While holding a burning, long hearth match or hand fire
starter, near the pilot head, depress the gas control knob
all the way down, and turn the knob in a counter-clockwise
direction, to the pilot position. Continue to hold the gas
control knob down for approximately one ( 1 ) minute, after
the pilot is lit.

10- Pilot should remain lit, and control knob should pop back

out when released. If not, repeat the aforementioned
steps. If pilot ignition does not take place, contact your
installer or the

fire

gear Service Center.

PILOT

ADJUSTMENT

SCREW

Summary of Contents for BFI18-SSMN

Page 1: ...ence INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WARNING If the information in this manual is not followed exactly a fire or explosion may result ca...

Page 2: ...cer birth defects and or other reproductive harm This warning is issued pursuant to California Health Safety Code Sec 25249 6 While this appliance is not in use the gas must be turned off at the gas s...

Page 3: ...ATURAL GAS RATED PRESSURE 7 0 W C MINIMUM GAS MAXIMUM GAS ORIFICE BTU HR PRESSURE PRESSURE SIZE INLET 7 0 W C 10 5 W C 13 90000 FIREGEAR FIRE ISLAND HEARTH SYSTEM SPECIFICATIONS with VALVE SAFETY PILO...

Page 4: ...r wall of the fireplace If this is not performed drafting may cause pilot outage or sooting Use a heat resistant sealant DO NOT seal the chimney flue damper WARNING Gas supply system must be installed...

Page 5: ...the wrench on the gas cap in a counter clockwise direction 4 Clean the pipe threads on the gas stub using either a wire brush or steel wool Apply Teflon tape or pipe dope to the steel fittings before...

Page 6: ...Using an adjustable wrench and turning in a clockwise direction attach a 1 2 Female Flare X 3 8 Male Flare Brass Reducer Fitting included on some models to the gas stub 4 Using two adjustable wrenches...

Page 7: ...r your distance run 1 The wire harness should already be installed in the terminal block on the rear of the remote receiver FOR HAND HELD TRANSMITTER REMOTE RECEIVERS SEE FIGURE 13 14 FOR WALL SWITCH...

Page 8: ...REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 13 14 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for directions on programming Learning both...

Page 9: ...s medium over the entire burner filling the burner pan The glass medium should follow the slope of the burner pan covering the burner completely SEE FIGURE 18 FIGURE 18 2 Pour the decorative sand arou...

Page 10: ...WITH VALVE FRONT VIEW WARNING Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and replace any part of the control s...

Page 11: ...smell gas STOP 7 Turn off the gas at the manual shut off valve and recheck all gas connections for leaks Do not continue until all leaks are corrected Once you are assured that there are no leaks pro...

Page 12: ...lve just to the right of the control knob SEE FIGURE 22 If the pilot flame must be adjusted use a standard slotted screwdriver to turn the screw clockwise to reduce the flame or counter clockwise to i...

Page 13: ...X 3 8 FLARE 50 12 38FL STUB FITTING BRASS ELBOW 1 2 NPT F X 3 8 M FLARE IM FIHS INSTRUCTION MANUAL FIRE ISLAND SERIES FG SAND B OPTIONAL FIRE ISLAND SERIES BLACK SAND LG H210 OPTIONAL FIRE ISLAND SERI...

Page 14: ...E KNOB EXTENSION FIREGEAR HAND HELD REMOTE SYSTEMS FG LT2 HAND HELD ON OFF REMOTE FG LMF M HAND HELD ON OFF VARIABLE FLAME REMOTE FIREGEAR WALL MOUNT REMOTE SYSTEMS FG WS LT WIRED WALL SWITCH FG WWS L...

Page 15: ...eck gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will...

Page 16: ...failures or operating difficulties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure to perform normal and routine m...

Reviews: