OPERATION & LIGHTING INSTRUCTIONS – MATCH THROW UNITS

FOR YOUR SAFETY – READ BEFORE LIGHTING

Natural Gas Match Throw Units, can be lit by long hearth
match, hand fire starter, or book match clip extender, inserted
near the center of the burner system.

1-

STOP!

Read all warnings and safety information in this

manual.

2-

WARNING:

BE SURE THAT THE CHIMNEY DAMPER

IS FULLY OPEN!

3-

Make sure that the manual shut-off valve, next to the
fireplace, is in the OFF position.

4-

Wait five ( 5 ) minutes to clear out any gas. If you smell
gas,

STOP!

Follow the safety instructions, “ WHAT TO

DO IF YOU SMELL GAS “, on the attached label, or on
page one ( 1 ) of this manual. If you do not smell gas,
continue with step five ( 5 ).

5-

Place a burning, long hearth match, or hand fire starter, on
top of the sand, near the center of the burner system.

6-

Slowly, turn on the gas, at the manual shut-off valve,
beside the fireplace, in a counter-clockwise direction. Gas
should ignite within approximately five ( 5 ) seconds.
Adjust burner flame by opening or closing manual gas
shut-off valve.

WARNING:

If ignition does not take place,

TURN THE GAS

OFF

, at the manual shut-off valve, and wait five ( 5 ) minutes,

before attempting to relight the appliance. If after repeated
attempts, the appliance does not ignite, contact your installer,
or the

fire

gear Service Center.

OPERATION – UNITS WITH GAS CONTROL VALVE

FOR YOUR SAFETY – READ BEFORE LIGHTING

FIGURE 20 – FIRE ISLAND BURNER PAN WITH VALVE – FRONT VIEW

!!! WARNING !!!

Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect the
appliance, and replace any part of the control system and any
gas control that has been under water.

All units with gas control valves, must be lit by a Safety Pilot.
For standard units, pilot is located at the rear, right-hand side
of the unit. ( SEE FIGURE 20 & 21 )

Follow these instructions exactly when lighting the appliance.
BEFORE LIGHTING, smell around the appliance area for gas.
Be sure to smell next to the floor, as LP gas is heavier than air
and will settle to the floor. Use only your hand to rotate the gas
control knob. Never use tools. If the knob will not turn by
hand, do not try to repair it; call qualified service technician or
installer. Force or attempted repair, may result in a fire or
explosion.

!!! WARNING !!!

All gas burning appliances produce smoke and carbon
monoxide gas during operation. These fumes can be harmful
if the appliance is used in any other than a fully vented
fireplace.

!!! WARNING !!!

A fireplace screen must be in place when this appliance is in
operation. Unless other provisions for combustion air are
provided, the screen shall have an opening(s) for introduction
of combustion air.

!!! WARNING !!!

When this decorative gas appliance is used in a fireplace
equipped with a combustion air kit and glass doors, the glass
doors should remain open during operation. This will maximize
the radiant heat provided to the surrounding area, and
minimize overheating of any valve installation. The glass
doors may be closed when the appliance is not in use.

Summary of Contents for BFI18-SSMN

Page 1: ...ence INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference WARNING If the information in this manual is not followed exactly a fire or explosion may result ca...

Page 2: ...cer birth defects and or other reproductive harm This warning is issued pursuant to California Health Safety Code Sec 25249 6 While this appliance is not in use the gas must be turned off at the gas s...

Page 3: ...ATURAL GAS RATED PRESSURE 7 0 W C MINIMUM GAS MAXIMUM GAS ORIFICE BTU HR PRESSURE PRESSURE SIZE INLET 7 0 W C 10 5 W C 13 90000 FIREGEAR FIRE ISLAND HEARTH SYSTEM SPECIFICATIONS with VALVE SAFETY PILO...

Page 4: ...r wall of the fireplace If this is not performed drafting may cause pilot outage or sooting Use a heat resistant sealant DO NOT seal the chimney flue damper WARNING Gas supply system must be installed...

Page 5: ...the wrench on the gas cap in a counter clockwise direction 4 Clean the pipe threads on the gas stub using either a wire brush or steel wool Apply Teflon tape or pipe dope to the steel fittings before...

Page 6: ...Using an adjustable wrench and turning in a clockwise direction attach a 1 2 Female Flare X 3 8 Male Flare Brass Reducer Fitting included on some models to the gas stub 4 Using two adjustable wrenches...

Page 7: ...r your distance run 1 The wire harness should already be installed in the terminal block on the rear of the remote receiver FOR HAND HELD TRANSMITTER REMOTE RECEIVERS SEE FIGURE 13 14 FOR WALL SWITCH...

Page 8: ...REMOTE RECEIVERS USE THE OUTSIDE TERMINAL BLOCK RECEPTACLES SEE FIGURE 13 14 WALL MOUNT REMOTE RECEIVER See the instructions packaged with the remote system for directions on programming Learning both...

Page 9: ...s medium over the entire burner filling the burner pan The glass medium should follow the slope of the burner pan covering the burner completely SEE FIGURE 18 FIGURE 18 2 Pour the decorative sand arou...

Page 10: ...WITH VALVE FRONT VIEW WARNING Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and replace any part of the control s...

Page 11: ...smell gas STOP 7 Turn off the gas at the manual shut off valve and recheck all gas connections for leaks Do not continue until all leaks are corrected Once you are assured that there are no leaks pro...

Page 12: ...lve just to the right of the control knob SEE FIGURE 22 If the pilot flame must be adjusted use a standard slotted screwdriver to turn the screw clockwise to reduce the flame or counter clockwise to i...

Page 13: ...X 3 8 FLARE 50 12 38FL STUB FITTING BRASS ELBOW 1 2 NPT F X 3 8 M FLARE IM FIHS INSTRUCTION MANUAL FIRE ISLAND SERIES FG SAND B OPTIONAL FIRE ISLAND SERIES BLACK SAND LG H210 OPTIONAL FIRE ISLAND SERI...

Page 14: ...E KNOB EXTENSION FIREGEAR HAND HELD REMOTE SYSTEMS FG LT2 HAND HELD ON OFF REMOTE FG LMF M HAND HELD ON OFF VARIABLE FLAME REMOTE FIREGEAR WALL MOUNT REMOTE SYSTEMS FG WS LT WIRED WALL SWITCH FG WWS L...

Page 15: ...eck gas supply pressure while pilot remains on Faulty Valve Replace Valve Faulty pilot or thermocouple Replace Safety Pilot Clogged or dirty burner ports Clean burner ports Burner pilot light but will...

Page 16: ...failures or operating difficulties due to accident abuse misuse alteration misapplication vandalism improper installation or improper maintenance or service or failure to perform normal and routine m...

Reviews: