C. HOSE WORK WITH RADIO REMOTE:
1. Begin with the engine around 1/4 throttle (1,400 RPM).
2. Close recirculation valve. If using an extension hose connected to the discharge boom, open the dis-
charge valve. If using the hose reel, close the discharge valve and open the pump take off valve to the
hose reel.
3. Switch Remote On/Off switch on the control panel to the "ON' position.
4. When the operator is in position, engage the pump using the remote transmitter and increase throttle to
the desired output.
IMPORTANT:
To quickly shut off the engine at any time, press the red "E-Stop" button on
the transmitter. To restart the engine, the key switch on the control panel must
be returned to the "OFF" position and then re-started.
5. When finished spraying, turn the pump off and decrease the engine throttle to idle.
CAUTION:
When using the radio remote control option, the secondary operator(s)
must be aware that the machine can be activated remotely at any time
after the Remote On/Off switch on the control panel is switched ON. If
any maintenance or troubleshooting needs to be performed while the
engine is running, the Remote On/Off switch must be in the off posi-
tion.
RELOADING PROCEDURE:
1. Start at step 2 in loading procedure on page 17.
2. After last load of the day refer to the cleaning and maintenance section of the manual on pages 26-35.
3. If the unit is equipped with an Air Flush System, refer to the Air Flush System Parts & Operator's
Manual.
LIMING WITH THE HYDROSEEDER
®
:
In using large concentrations of granular solids through the HydroSeeder
®
, it is advisable to keep the slurry
moving through the pump at all times. This keeps the solids from settling in the lines, and creating a stoppage.
This unit was designed for the application of agricultural grade lime only.
PROCEDURE:
1. With clutch disengaged and agitator control in neutral position, start engine and allow it to warm up
(see starting procedure on page 12).
2. Start filling the unit with water. When water reaches the top of the agitator shaft move agitator con-
trol to approximately 1/2 speed reverse.
3. Open both the recirculation and discharge valves.
4. Remove the discharge nozzle and gasket from the discharge boom.
21
Summary of Contents for HydroSeeder T280
Page 2: ...NOTES...
Page 9: ...CURRENT SET OF SAFETY DECALS 5...
Page 32: ...28 4 3 8 3 3 9 11 10 13 1 5 12 9 6 2 7 3...
Page 40: ...36 NOTES...
Page 41: ...37 NOTES...
Page 42: ...38 NOTES...
Page 43: ...39 NOTES...
Page 44: ...40 NOTES...
Page 45: ...T280 330 HydroSeeder Parts Manual Model SE 41 LBT289 T330 SE...
Page 46: ...NOTES 42...
Page 58: ...54 WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE...
Page 83: ...79 NOTES...