
When adding these roles or functions, you will need to use the ‘programming
pages’ which are accessed using the corresponding P key. For example, Page 2
is accessed by selecting [P2]. See below:
Table 2 Programming Page Functions
Page
Function
Description
1
Assigning
partitions
Select the partition number followed by [*] to add
or remove partitions to and from a user’s profile.
Only partitions belonging to the profile of the
master code used to access programming mode may
be added or removed.
2
Assigning
user type
Touch the user type number followed by [*] to
enable and disable the options as per the user type
table below.
3
Add remote
functionality
Touch any button on an unused remote in order to
enrol it to this user. Only 1 remote may be assigned
per user code and only one user may be assigned to
a remote.
4
View the user
number
The user number is displayed in binary format.
You will also have to select a user type. See below for the options:
Table 3 User Type Values
Values
User Type
Description
1
Master
Can add/remove and edit user codes
2
Duress
A duress code will disarm the panel normally and a
duress signal will be sent to the alarm monitoring
company. This signals that a user has been forced to
disarm the panel under duress.
3
Arm to
Disarm
This code will only disarm a partition if the same
Arm to Disarm code was used to arm. This code
may be given to a user whom has limited access to
the premises.
4
Global
Arm/Disarm
A Global code will simultaneously arm and disarm
all partitions in a users profile. All partitions will
follow the status of the partition which was selected
at the time the code was entered.
5
Reporting
The user code will report an open and a close when
arming and disarming.