TYPE OF MAINTENANCE
AT THE END
OF THE
WORK
DAILY
WEEKLY
BEFORE
A LONG
PERIOD OF
NON-USE
TRANSPORT
EMPTYING THE SOLUTION TANK
X
X
X
CLEANING THE WATER SYSTEM FILTER
X
X
ROUTINE MAINTENANCE
Before carrying out any routine maintenance operations, proceed as follows:
1. Take the machine to the maintenance area.
WARNING:
the place designated for this operation must comply with current regulations concerning safety at work and current
environmental protection regulations.
2.
Carry out the steps necessary to secure the machine, see paragraph “MACHINE SAFETY” on page 17.
ATTENTION:
It is recommended to wear the appropriate PPE (Personal Protective Equipment), suitable for the work to be carried out.
EMPTYING THE SOLUTION TANK
Proceed as follows to empty the solution tank:
1.
Close the tap's output flow, and shift the knob (1) on the left hand side of the steering column (
Fig.1
) downward.
2.
Remove the sanitizing solution filter cap (2) (
Fig.2
).
3.
Open the tap's output flow, and shift the knob (1) on the left hand side of the steering column upward.
4. When the solution tank is empty, repeat the operations in the reverse order to reassemble all the parts.
CLEANING THE WATER SYSTEM FILTER
In order to clean the water system's filter, do the following:
1.
Close the tap's output flow, and shift the knob (1) on the left hand side of the steering column (
Fig.1
) downward.
2.
Remove the sanitizing solution filter cap (2) (
Fig.2
).
3.
Rinse the filter cartridge under a jet of water, and use a brush to eliminate any impurities, if necessary.
4.
Once the filter cartridge is clean, repeat the operations in the opposite order to reassemble all the parts.
DISPOSAL
Proceed with scrapping the machine in accordance with the waste disposal regulations in force in the country in which the
machine is being used.
23
2
1
1
2
Summary of Contents for BMg Sanitizer
Page 1: ...ORIGINAL INSTRUCTION DOC 10095868 Ver AA 03 2020 USE AND MAINTENANCE MANUAL BMg Sanitizer...
Page 2: ......