background image

 

 

COPYRIGHT INFORMATION 

©2018, Fike Corporation. All rights reserved. Printed in the U.S.A. 

This document may not be reproduced, in whole or in part, by any means without the prior written consent of Fike. 
All Fike documentation and hardware are copyrighted with all rights reserved. 

TRADEMARKS 

Fike®, SHP-Pro®, Cheetah® Xi, CyberCat®, DuraQuench™, Precise Vision™, EPACO®  

are registered trademarks of 

Fike. All other trademarks, trade names, or company names referenced herein are the property of their respective 
owners. 

ERRORS AND OMMISSIONS 

While  every  precaution  has  been  taken  during  the  preparation  of  this  document  to  ensure  the  accuracy  of  its 
content, Fike assumes no responsibility whatsoever for errors or omissions. 

Fike reserves the right to change product designs or specifications without obligation and without further notice in 
accordance with our policy of continuing product and system improvement. 

READER QUESTIONS AND RESPONSES 

If you have any questions regarding the information contained in this document, or if you have any other inquiries 
regarding Fike products, please call Fike’s Customer Support Department at (800)-979-FIKE (3453), option 21. 

Fike encourages input from our distributors and end users on how we can improve this manual and even the product 
itself. Please contact us at 

[email protected]

Any communication received becomes the property of Fike. 

TERMS AND CONDITIONS OF SALE 

Because of the many and varied circumstances and extreme condition under which Fike’s products are used, and 
because Fike has no control over this actual use, Fike makes no warranties based on the contents of this document. 
FIKE  MAKES  NO  IMPLIED  WARRANTIES  OF  MERCHANTABILITY  OR  FITNESS  FOR  A  SPECIFIC  PURPOSE.  Refer  to 

www.fike.com/terms-conditions

 for Fike’s full TERMS AND CONDITIONS OF SALE. 

TERMS OF USE 

Do not alter, modify, copy, or otherwise misappropriate any Fike product, whether in whole or in part. Fike assumes 
no responsibility for any losses incurred by you or third parties arising from such alteration, modification, copy, or 
otherwise misappropriation of Fike products. 

Do not use any Fike products for any application for which it is not intended. Fike shall not be in any way liable for 
any damages or losses incurred by you or third parties arising from the use of any Fike product for which the product 
is not intended by Fike. 

You should install and use the Fike products described in this document within the range specified by Fike, especially 
with respect to the product application, maximum ratings, operating supply voltage range, installation and other 
product characteristics. Fike shall have no liability for malfunctions or damages arising out of the use of Fike products 
beyond such specified ranges. 

You  should  install  and  use  the  Fike  products  described  in  this  document  in  compliance  with  all  applicable  laws, 
standards,  and  regulations.  Fike  assumes  no  liability  for  damages  or  losses  occurring  as  a  result  of  your 
noncompliance with applicable laws and regulations. 

It is the responsibility of the buyer or distributor of Fike products, who distributes, disposes of, or otherwise places 
the product with a third party, to notify such third party in advance of the contents and conditions set forth in this 
document. Fike assumes no responsibility for any losses incurred by you or third parties as a result of unauthorized 
use of Fike products. 

QUALITY NOTICE 

Fike  is  an  ISO  9001:2015  certified  company.  Prior  to  shipment,  we  thoroughly  test  our  products  and  review  our 
documentation to assure the highest quality in all respects. 

 

Summary of Contents for 10-2983

Page 1: ...SOLUTIONS Fire Protection Explosion Protection Overpressure Protection Pressure Activation Doc P N 06 905 Rev 1 December 2018 PRODUCT MANUAL Output Analyzer P N 10 2983...

Page 2: ......

Page 3: ...R FITNESS FOR A SPECIFIC PURPOSE Refer to www fike com terms conditions for Fike s full TERMS AND CONDITIONS OF SALE TERMS OF USE Do not alter modify copy or otherwise misappropriate any Fike product...

Page 4: ......

Page 5: ...urrent Test 8 7 3 3 Test 3 EPC Field Test 9 7 3 4 Test 4 Field Wiring Supervisory Current Test 10 8 0 IRM TESTING 11 8 1 IRM Operational Overview 11 8 2 Interpreting IRM Measured Results 11 8 3 IRM Te...

Page 6: ...ng Circuit Activation Current 6 Figure 7 3 2 1 EPC Series Firing Circuit Supervisory Current Test 8 Figure 7 3 3 1 Field Wiring Activation Current Test 9 Figure 8 3 1 IRM Circuit Activation Current Te...

Page 7: ...er EPC P N E10 0066 Impulse Release Module IRM P N 10 2748 Fire Agent Release Module Fire ARM P N 10 1832 Explosion Protection Agent Release Module EP ARM P N E10 010 The device s portability and ease...

Page 8: ...ing cord but does not come with a wall charger or a 1 Ohm Resistor used in EPC testing Please obtain a charger to fully charge the battery before testing To ensure this device remains compliant with E...

Page 9: ...r modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This product complies with the essential requirements of the fo...

Page 10: ...attery charge is displayed on initial power up and you can check it periodically by using Option 7 Chk Batt Chrg to keep track of usage 6 0 CONTROLS INTERFACE On initial power up the battery charge wi...

Page 11: ...ttery charge is displayed on initial power and can be viewed at any time under Option 7 of the main menu 7 0 EPC TESTING 7 1 EPC Operational Overview The Output Analyzer is used to perform two importa...

Page 12: ...he end of its useful life and should be replaced For the EPC the average of the four test readings must be greater than or equal to 95 of 3 amps or 2 85A If the average is approaching 2 85A consider r...

Page 13: ...gs obtained during the test EPC PASSES REPLACE EPC will display on the front panel of the Analyzer See Section 7 2 Interpreting EPC Measured Results for more information or if you have questions regar...

Page 14: ...lyzer wait the three seconds for the battery charge status to flash then press and release the SELECT button to arrive at the EPC Tool menu Option 1 press the ENTER button to choose this option The su...

Page 15: ...are disconnected except at the field box under testing 4 At the field box under testing install short wire leads into the GCA firing circuit terminals 5 On the first field box to be tested use the 14...

Page 16: ...zer test verifies the supervisory current being supplied by the EPC to the field devices through series firing circuit field wiring The Analyzer comes with jumpers and test leads used to perform this...

Page 17: ...upplying adequate firing current with readings occurring momentarily there is a slight delay between fire control panel activation and firing circuit release IMPORTANT The Output Analyzer ACTIVATE but...

Page 18: ...me 4 Wait 60 seconds to allow the capacitors time to charge If the panel does not immediately return to normal reset the panel to a normal state 5 Remove the 0 Shunt from the Analyzer The supervisory...

Page 19: ...about 10 min then shunt all GCA s per 06 106 ARM III Rev 2 connected to the system before proceeding 2 Connect the Analyzer to the ARM as shown in Figure 9 3 1 below Figure 9 3 1 Fire ARM Circuit Act...

Page 20: ...upply the correct current amps required to activate the actuator devices connected to the firing circuit the second testing function assesses the integrity of the field wiring by measuring the supervi...

Page 21: ...Ready for Test Reset the main EP Control Panel if required to obtain a normal panel and wait 60 seconds for the capacitor to charge 6 Activate the EP ARM by initiating a detection input that will caus...

Page 22: ...with any battery operated device the battery in the Output Analyzer should be charged periodically using a typical USB C 5Vdc connection Ensure the voltage rating of the connection is 5Vdc maximum or...

Reviews: