Opening the E100
As part of servicing the E100, you may need to open the E100.
When you handle electronic components, you must follow standard electrostatic discharge
(ESD) precautions. For more information, see
“Standard electrostatic discharge precautions”
F
IGURE
5:
Opening the E100
T
O
OPEN
THE
E100
1. Shut down the E100 and the copier (see
).
2. Disconnect all external cables from the E100 connector panel.
3. Remove the four screws that attach the E100 to the copier.
4. Remove the E100 from the copier.
For detailed information about removing/installing the E100, see the installation instructions
that accompany the copier (not included in this document).
5. Place the E100 on a flat surface and remove the two screws that secure the cover of the E100
to the chassis (see
Set aside the screws so that you can replace them later.
6. Raise the cover and slide it toward the connector panel of the chassis to remove it.
Set aside the cover so that you can replace it later.
The E100 internal components are now accessible.