FS-8700-48 Fike Cheetah Manual
Page 35 of 36
FieldServer Technologies
1991 Tarob Court Milpitas, California 95035 USA
Web
: www.fieldserver.com
Tel
: (408) 262 2299
Fax
: (408) 262 2269
Toll Free
: (888) 509 1970
# Description
Notes
168 checksum ok -----
board level output config checksum restored. circuit number appended to this
message.
169 checksum error -----
board level output config checksum error. circuit number appended to this
message.
170 password level 1
password level 1 enterred.
171 password level 2
password level 2 enterred.
172 password level 3
password level 3 enterred.
173 password level 4
password level 4 enterred.
174 password level 5
password level 5 enterred.
175 password expired
password has timed-out.
176 software error
erroneous interrupt source or illegal program instruction fetched.
177 keyword error
erroneous program flow.
178 wiring fault restore
frcm/som/srm wiring fault restored to normal.
179 config resto 4: sens
config error #4 restored
180 config error 4: sens
config error #4 (analog phot has too high alarm sensitivity)
181 bat1 charge volt low battery #1 charger has a low voltage output
182 bat1 charge restored battery #1 chrager has returned to normal voltage output
183 bat2 charge volt low battery #2 charger has a low voltage output
184 bat2 charge restored battery #2 chrager has returned to normal voltage output
185 cfg resto 5: w------
config error #5 restored. zone number appended.
186 cfg error 5: w------
config error #5 (watermist zone needs an srm). zone number appended.
187 cfg resto 6: w------
config error #6 restored. zone number appended.
188 cfg error 6: w------
config error #6 (watermist zone has an abort). zone number appended.
189 cfg resto 7: on-time
config error #7 restored
190 cfg error 7: on-time
config error #7 (srm assigned to watermist & zone has no on-time)
191 cfg resto 8: zn-type
config error #8 restored.
192 cfg error 8: zn-type
config error #8 (srm assigned to watermist & alarm type of zone).
193 pc configuring panel configuration is currently being changed by the pc
194 pc configuring done the pc has finished configuring the panel
195 history is erased
the history buffers have been erased
196 cfg resto 10: vesda#
config error #10 restored
197 vesda commun error communication to the vesda hli device has failed
198
vesda
commun
restore
communication to the vesda hli device has restored to normal
199 cfg error 10: vesda#
config error #10 (two vesda's with the same unit number)
200 alert level restore
vesda detector alert level restored. analog data appended to this message
201 alert 0.000%/0.000% vesda detector alert level activated. analog data appended to this message
202 action level restore
vesda detector action level restored. analog data appended to this message
203 action 0.000%/0.000% vesda detector action level activated. analog data appended to this message
204 fire-1 0.000%/0.000% vesda detector fire 1 level activated. analog data appended to this message
205 fire-2 0.000%/0.000% vesda detector fire 2 level activated. analog data appended to this message
206 vesda fault: major
vesda detector trouble
207 vesda clear: major
vesda detector trouble