FS-8700-48 Fike Cheetah Manual
Page 34 of 36
FieldServer Technologies
1991 Tarob Court Milpitas, California 95035 USA
Web
: www.fieldserver.com
Tel
: (408) 262 2299
Fax
: (408) 262 2269
Toll Free
: (888) 509 1970
# Description
Notes
126 calibration fault
fault detected during calibration of this device.
127 configure restored
fault restored from som/r2m/srm configuration trouble.
128 configure fault
fault detected when configuring som/r2m/srm.
129 reconfigured device addressable device has been configured
130 enabled device
addressable device has been enabled.
131 disabled device
addressable device has been disabled.
132 enabled loop 1
loop 1 has been enabled.
133 disabled loop 1
loop 1 has been disabled.
134 enabled loop 2
loop 2 has been enabled.
135 disabled loop 2
loop 2 has been disabled.
136 enabled loop 3
loop 3 has been enabled.
137 disabled loop 3
loop 3 has been disabled.
138 enabled loop 4
loop 4 has been enabled.
139 disabled loop 4
loop 4 has been disabled.
140 enabled zone -----
zone enabled. zone number appended to this message.
141 disabled zone -----
zone disabled. zone number appended to this message.
142 enabled ckt -----
board level output circuit enabled. circuit number appended to this message.
143 disabled ckt -----
board level output circuit disabled. circuit number appended to this message.
144 loop 1 calibration
all configured analog devices on loop 1 have been calibrated.
145 loop 2 calibration
all configured analog devices on loop 2 have been calibrated.
146 loop 3 calibration
all configured analog devices on loop 3 have been calibrated.
147 loop 4 calibration
all configured analog devices on loop 4 have been calibrated.
148 l1 open class a
class a wiring has an open circuit trouble - loop 1.
149 l2 open class a
class a wiring has an open circuit trouble - loop 2.
150 l3 open class a
class a wiring has an open circuit trouble - loop 3.
151 l4 open class a
class a wiring has an open circuit trouble - loop 4.
152 l1 class a restored
class a wiring trouble has restored to noramal - loop 1.
153 l2 class a restored
class a wiring trouble has restored to noramal - loop 2.
154 l3 class a restored
class a wiring trouble has restored to noramal - loop 3.
155 l4 class a restored
class a wiring trouble has restored to noramal - loop 4.
156 walktest active
panel has enterred the walktest mode.
157 walktest expired
walktest mode has expired.
158 cfg resto 1: mr-----
config error #1 restored. zone number appended to this message.
159 cfg error 1: mr-----
config error #1 (no manrel in this zone). zone number appended to this message.
160
cheetah network device clear
161
cheetah network device activation
162 config resto 3: al v
config error #3 restored.
163 config error 3: al v
config error #3 (alarm verification on device in a suppression zone) trouble.
164 system power low system power below voltage level for reliable operation.
165 system power ok
system power low trouble restored.
166 checksum error -----
config checksum error trouble: devices & loops (loop number appended).
167 checksum ok -----
config checksum error trouble restored: devices & loops (loop number appended).