3. Verify correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
Connection with DHT22
The DHT22 sensor may easily be installed wherever humidity and temperature measurements are required.
You can connect only 1 DHT22 sensor to TP-TD terminals.
1. Disconnect Power
2. Connect with the diagram below
3. Verify correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
6. Change values of parameters:
Connected to IN1: change parameter 20 to 4
Connected to IN2: change parameter 21 to 4
Connection with 2-wire 0-10V Sensor
The 2-wire analog sensor requires pull-up resistor.
You can connect up to 2 analog sensors to IN1/IN2 terminals.
The 12V supply is required for these type of sensors.
1. Disconnect Power
2. Connect with the diagram below
3. Verify the correctness of connection.
4. Power the device.
5. Add the device to the Z-Wave network.
6. Change values of parameters:
Connected to IN1: change parameter 20 to 5
Connected to IN2: change parameter 21 to 5