FIBARO FIBEFGBS-222 Manual Download Page 12

Association V2

Basic

Central Scene V3

Configuration

Crc 16 Encap

Device Reset Locally

Firmware Update Md V4

Manufacturer Specific V2

Multi Channel Association V3

Multi Channel V4

Notification V8

Powerlevel

Protection V2

Security

Security 2

Sensor Multilevel V11

Supervision

Switch Binary

Transport Service V2

Version V2

Zwaveplus Info V2

Controlled Command Classes

Basic

Explanation of Z-Wave specific terms

Controller

 — is a Z-Wave device with capabilities to manage the network. Controllers are typically Gateways,Remote Controls or battery operated wall

controllers.

Slave

 — is a Z-Wave device without capabilities to manage the network. Slaves can be sensors, actuators and even remote controls.

Primary Controller

 — is the central organizer of the network. It must be a controller. There can be only one primary controller in a Z-Wave network.

Inclusion

 — is the process of adding new Z-Wave devices into a network.

Exclusion

 — is the process of removing Z-Wave devices from the network.

Association

 — is a control relationship between a controlling device and a controlled device.

Wakeup Notification

 — is a special wireless message issued by a Z-Wave device to announces that is able to communicate.

Node Information Frame

 — is a special wireless message issued by a Z-Wave device to announce its capabilities and functions.

(c) 2020 Z-Wave Europe GmbH, Antonstr. 3, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwave.eu. The template is maintained by 

Z-Wave

Europe GmbH

. The product content is maintained by Z-Wave Europe GmbH , Supportteam, [email protected]. Last update of the product data: 2020-10-02

09:40:24

Summary of Contents for FIBEFGBS-222

Page 1: ...mation about Z Wave technology devices white papers etc please refer to www z wave info Product Description FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z Wave network communication You can connect binary sensors analog sensors DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z Wave control...

Page 2: ...ection with regular alarm line 1 alarm sensor 2 alarm system hub Example connection with parametric alarm line 1 alarm sensor 2 alarm system hub 3 Verify correctness of connection 4 Arrange the device and its antenna in the housing 5 Power the device 6 Add the device to the Z Wave network 7 Change values of parameters Connected to IN1 Normally close change parameter 20 to 0 Normally open change pa...

Page 3: ...o the Z Wave network 6 Change values of parameters Connected to IN1 change parameter 20 to 4 Connected to IN2 change parameter 21 to 4 Connection with 2 wire 0 10V Sensor The 2 wire analog sensor requires pull up resistor You can connect up to 2 analog sensors to IN1 IN2 terminals The 12V supply is required for these type of sensors 1 Disconnect Power 2 Connect with the diagram below 3 Verify the ...

Page 4: ...ry sensors to IN1 IN2 terminals 1 Disconnect Power 2 Connect with the diagram below 3 Verify the correctness of connection 4 Power the device 5 Add the device to the Z Wave network 6 Change values of parameters 6 1 Binary sensor Connected to IN1 Normally close change parameter 20 to 0 Normally open change parameter 20 to 1 Connected to IN2 Normally close change parameter 21 to 0 Normally open chan...

Page 5: ...ht on the device Inclusion 1 Power the device 2 Set the main controller in Security non Security Mode add mode see the controllers manual 3 Quickly triple click button on the device housing or switch connected to IN1 or IN2 4 If you are adding in Security S2 Authenticated scan the DSK QR code or input the 5 digit PIN code label on the bottom of the box 5 LED will start blinking yellow wait for the...

Page 6: ...ommunication with the main controller through other modules repeaters Visual indicator glowing yellow the device communicates with the main controller through the other modules After 2 seconds the device will retry to establish a direct communication with the main controller which will be signalled with visual indicator pulsing green Visual indicator pulsing violet the device does communicate at t...

Page 7: ...ired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device To wakeup the device please perform the following action FIBARO Smart Implant is powered using DC power supply unit so it...

Page 8: ...ntral Scene 3 Bistable button Central Scene 4 Analog input without internal pull up Sensor Multilevel 5 Analog input with internal pullup Sensor Multilevel Parameter 21 Input 2 operating mode This parameter allows to choose mode of 2nd input Size 1 Byte Default Value 2 Setting Description 0 Normally closed alarm input Notification CC 1 Normally open alarm input Notification CC 2 Monostable button ...

Page 9: ...Input 2 value sent to 3rd association group when activated This parameter defines value sent to devices in 3rd association group when IN2 input is triggered using Basic Command Class Size 2 Byte Default Value 255 Setting Description 0 255 value send to devices Parameter 54 Input 2 value sent to 3rd association group when deactivated This parameter defines value sent to devices in 2nd association g...

Page 10: ... connected DS18B20 or DHT22 sensors Size 2 Byte Default Value 0 Setting Description 0 periodical reports disabled 60 32400 60s 9h Parameter 150 Input 1 sensitivity This parameter defines the inertia time of IN1 input in alarm modes Adjust this parameter to prevent bouncing or signal disruptions Parameter is relevant only if parameter 20 is set to 0 or 1 alarm mode Size 1 Byte Default Value 10 Sett...

Page 11: ...e 2 Byte Default Value 0 Setting Description 0 auto off disabled 1 27000 0 1s 45min 0 1s step Parameter 157 Output 2 auto off This parameter defines time after which OUT2 will be automatically deactivated Size 2 Byte Default Value 0 Setting Description 0 auto off disabled 1 27000 0 1s 45min 0 1s step Technical Data Dimensions 17 5 x 29 x 13 mm Hardware Platform ZM5101 EAN 5902701701475 IP Class IP...

Page 12: ...ry Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special...