This parameter defines minimal change (from the last reported) of internal temperature sensor value that results in sending new report.
Size: 2 Byte, Default Value: 5
Setting
Description
0
reporting on change disabled
1 - 255
(0.1-25.5C)
Parameter 66: Internal temperature sensor - periodical reports
This parameter defines reporting period of internal temperature sensor value. Periodical reports are independent from changes in value (parameter 65).
Size: 2 Byte, Default Value: 0
Setting
Description
0
periodical reports disabled
60 - 32400
(60s-9h)
Parameter 67: External sensors - minimal change to report
This parameter defines minimal change (from the last reported) of external sensors values (DS18B20 or DHT22) that results in sending new report. Parameter is
relevant only for connected DS18B20 or DHT22 sensors.
Size: 2 Byte, Default Value: 5
Setting
Description
0
reporting on change disabled
1 - 255
(0.1-25.5 units, 0.1)
Parameter 68: External sensors - periodical reports
This parameter defines reporting period of analog inputs value. Periodical reports are independent from changes in value (parameter 67). Parameter is relevant
only for connected DS18B20 or DHT22 sensors.
Size: 2 Byte, Default Value: 0
Setting
Description
0
periodical reports disabled
60 - 32400
(60s-9h)
Parameter 150: Input 1 - sensitivity
This parameter defines the inertia time of IN1 input in alarm modes. Adjust this parameter to prevent bouncing or signal disruptions.Parameter is relevant only if
parameter 20 is set to 0 or 1 (alarm mode).
Size: 1 Byte, Default Value: 10
Setting
Description
1 - 100
(10ms-1000ms, 10ms step)
Parameter 151: Input 2 - sensitivity
This parameter defines the inertia time of IN2 input in alarm modes. Adjust this parameter to prevent bouncing or signal disruptions. Parameter is relevant only if
parameter 21 is set to 0 or 1 (alarm mode).
Size: 1 Byte, Default Value: 10
Setting
Description
1 - 100
(10ms-1000ms, 10ms step)
Parameter 152: Input 1 - delay of alarm cancellation
This parameter defines additional delay of cancelling the alarm on IN1 input. Parameter is relevant only if parameter 20 is set to 0 or 1 (alarm mode).
Size: 2 Byte, Default Value: 0
Setting
Description
0
no delay
1 - 3600
(in seconds)
Parameter 153: Input 2 - delay of alarm cancellation
This parameter defines additional delay of cancelling the alarm on IN2 input. Parameter is relevant only if parameter 21 is set to 0 or 1 (alarm mode).
Size: 2 Byte, Default Value: 0
Setting
Description
0
no delay
1 - 3600
(in seconds)