FIBARO FIBEFGBS-222 Manual Download Page 1

Fibaro

Smart Implant

SKU: FIBEFGBS-222

 

 

Quickstart

This is a 

secure Alarm Sensor 

for 

Europe

. To run this device please connect it to your mains power supply. 

1.Set the main controller in Security S2 Authenticated add mode (see the controllers manual). 

 

2.Scan the DSK QR code or input the 5-digit PIN code (label on the bottom of the box).

 

3.Power the device.

 

4.LED will start blinking yellow, wait for the adding process to end.

 

5.Successful adding will be confirmed by the Z-Wave controllers message.

 
 

Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer,
distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this
equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources. 

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (

two-way communication

) and

every mains powered node can act as a repeater for other nodes (

meshed network

) in case the receiver is

not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be 

used together with any other certified Z-

Wave device regardless of brand and origin 

as long as both are suited for the same frequency range.

If a device supports 

secure communication

 it will communicate with other devices secure as long as this

device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level
of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z-Wave network communication.You can connect binary
sensors, analog sensors, DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z-Wave controller.It can also
control devices by opening/closing output contacts independently of the inputs.Main features of FIBARO Smart Implant:- Compatible with any Z-Wave or Z-Wave+
Controller,- Supports Z-Wave network Security Modes: S0 with AES-128 encryption and S2 with PRNG-based encryption,- Allows for connecting sensors: o6
DS18B20 sensors,o1 DHT sensor, o2 2-wire analog sensor, o2 3-wire analog sensor, o2 binary sensors. - Works as a Z-Wave signal repeater,- Built-in
temperature sensor.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it 

must be in factory default state.

 Please make sure to reset the device into factory default. You can do

this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended
to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

1.Press and hold the button to enter the menu.

 

2.Release button when the device glows yellow.

 

3.Quickly click the button to confirm.

 

4.After few seconds the device will be restarted, which is signalled with the red colour.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the
assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Summary of Contents for FIBEFGBS-222

Page 1: ...mation about Z Wave technology devices white papers etc please refer to www z wave info Product Description FIBARO Smart Implant allows to enhance the functionality of wired sensors and other devices by adding Z Wave network communication You can connect binary sensors analog sensors DS18B20 temperature sensors or DHT22 humidity and temperature sensor to report their readings to the Z Wave control...

Page 2: ...ection with regular alarm line 1 alarm sensor 2 alarm system hub Example connection with parametric alarm line 1 alarm sensor 2 alarm system hub 3 Verify correctness of connection 4 Arrange the device and its antenna in the housing 5 Power the device 6 Add the device to the Z Wave network 7 Change values of parameters Connected to IN1 Normally close change parameter 20 to 0 Normally open change pa...

Page 3: ...o the Z Wave network 6 Change values of parameters Connected to IN1 change parameter 20 to 4 Connected to IN2 change parameter 21 to 4 Connection with 2 wire 0 10V Sensor The 2 wire analog sensor requires pull up resistor You can connect up to 2 analog sensors to IN1 IN2 terminals The 12V supply is required for these type of sensors 1 Disconnect Power 2 Connect with the diagram below 3 Verify the ...

Page 4: ...ry sensors to IN1 IN2 terminals 1 Disconnect Power 2 Connect with the diagram below 3 Verify the correctness of connection 4 Power the device 5 Add the device to the Z Wave network 6 Change values of parameters 6 1 Binary sensor Connected to IN1 Normally close change parameter 20 to 0 Normally open change parameter 20 to 1 Connected to IN2 Normally close change parameter 21 to 0 Normally open chan...

Page 5: ...ht on the device Inclusion 1 Power the device 2 Set the main controller in Security non Security Mode add mode see the controllers manual 3 Quickly triple click button on the device housing or switch connected to IN1 or IN2 4 If you are adding in Security S2 Authenticated scan the DSK QR code or input the 5 digit PIN code label on the bottom of the box 5 LED will start blinking yellow wait for the...

Page 6: ...ommunication with the main controller through other modules repeaters Visual indicator glowing yellow the device communicates with the main controller through the other modules After 2 seconds the device will retry to establish a direct communication with the main controller which will be signalled with visual indicator pulsing green Visual indicator pulsing violet the device does communicate at t...

Page 7: ...ired wakeup interval and the node ID of the controller If the device was included by a static controller this controller will usually perform all necessary configurations The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device To wakeup the device please perform the following action FIBARO Smart Implant is powered using DC power supply unit so it...

Page 8: ...ntral Scene 3 Bistable button Central Scene 4 Analog input without internal pull up Sensor Multilevel 5 Analog input with internal pullup Sensor Multilevel Parameter 21 Input 2 operating mode This parameter allows to choose mode of 2nd input Size 1 Byte Default Value 2 Setting Description 0 Normally closed alarm input Notification CC 1 Normally open alarm input Notification CC 2 Monostable button ...

Page 9: ...Input 2 value sent to 3rd association group when activated This parameter defines value sent to devices in 3rd association group when IN2 input is triggered using Basic Command Class Size 2 Byte Default Value 255 Setting Description 0 255 value send to devices Parameter 54 Input 2 value sent to 3rd association group when deactivated This parameter defines value sent to devices in 2nd association g...

Page 10: ... connected DS18B20 or DHT22 sensors Size 2 Byte Default Value 0 Setting Description 0 periodical reports disabled 60 32400 60s 9h Parameter 150 Input 1 sensitivity This parameter defines the inertia time of IN1 input in alarm modes Adjust this parameter to prevent bouncing or signal disruptions Parameter is relevant only if parameter 20 is set to 0 or 1 alarm mode Size 1 Byte Default Value 10 Sett...

Page 11: ...e 2 Byte Default Value 0 Setting Description 0 auto off disabled 1 27000 0 1s 45min 0 1s step Parameter 157 Output 2 auto off This parameter defines time after which OUT2 will be automatically deactivated Size 2 Byte Default Value 0 Setting Description 0 auto off disabled 1 27000 0 1s 45min 0 1s step Technical Data Dimensions 17 5 x 29 x 13 mm Hardware Platform ZM5101 EAN 5902701701475 IP Class IP...

Page 12: ...ry Controller is the central organizer of the network It must be a controller There can be only one primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special...

Reviews: