29
Z-Wave specIfIcatIon
Notification Command Class
The device uses Notification Command Class to report different events
to the controller using “Lifeline” group (only in Root / Endpoint 1).
Notification
Type
Event
Parameter
Status
System [0x09] Heartbeat (Notifica-
tion CC V5) [0x05]
–
0xFF – enable
(non-changeable)
Protection CC
Protection Command Class allows to prevent local or remote control
of the outputs.
Type State
Description
Hint
Local
0
Unprotected - The device is not
protected, and may be operated
normally via the user interface.
Inputs connected
with outputs.
Local
2
No operation possible – button can
not change relay state, any other
functionality is available (menu and
Central Scenes Notification).
Inputs disconnect-
ed from outputs.
RF
0
Unprotected - The device accept
and respond to all RF Commands.
Outputs can be
controlled via
Z-Wave.
RF
1
No RF control – command class ba-
sic and switch binary are rejected,
every other command class will be
handled.
Outputs cannot
be controlled via
Z-Wave.
Assocation groups mapping
Root
Endpoint
Association group in
endpoint
Association Group 2
Endpoint 1
Association Group 2
Association Group 3
Endpoint 2
Association Group 2