24
confIguratIon
155.
Second channel – time parameter for delayed/auto
OFF and flashing modes
Only in Double Smart Module
Description
This parameter allows to set time parameter
used in timed modes for second channel. For
delayed/auto OFF modes it determines duration,
for flashing mode it determines cycle period.
Parameter size
2B
Default value
5 (0.5s)
Available
values
0 – 0.1 seconds
1-32000 – 0.1-3200 seconds, 0.1s step
156.
S1 input – Switch ON value sent to 2nd association
group
Description
This parameter defines value sent with Switch
ON command to devices in 2nd association
group when using S1 input.
Parameter size
2B
Default value
255
Available
values
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
157.
S1 input – Switch OFF value sent to 2nd association
group
Description
This parameter defines value sent with Switch
OFF command to devices in 2nd association
group when using S1 input.
Parameter size
2B
Default value
0
Available
values
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
158.
S1 input – Double Click value sent to 2nd association
group
Description
This parameter defines value sent with Double
Click command to devices in 2nd association
group when using S1 input.
Parameter size
2B
Default value
99
Available
values
0 – turn off
1-99 – turn on and set level
255 – turn on with last level