32.
Alarm configuration - 3rd slot
Description
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
Parameter size
4B
Default value
[0x01, 0xFF, 0x00, 0x00]
(Smoke Alarm, any notification, no action)
Available
values
1B
[MSB] – Notification Type
2B
– Notification Status
3B
– Event/State Parameters
4B
[LSB] – action:
0x00
– no action,
0x01
– turn ON,
0x02
– turn
OFF,
0x03
– turn ON/OFF continuously
33.
Alarm configuration - 4th slot
Description
This parameter determines to which alarm
frames and how the device should react. The
parameters consist of 4 bytes, three most sig-
nificant bytes are set according to the official
Z-Wave protocol specification.
Parameter size
4B
Default value
[0x02, 0xFF, 0x00, 0x00]
(CO Alarm, any notification, no action)
Available
values
1B
[MSB] – Notification Type
2B
– Notification Status
3B
– Event/State Parameters
4B
[LSB] – action:
0x00
– no action,
0x01
– turn ON,
0x02
– turn
OFF,
0x03
– turn ON/OFF continuously