25
confIguratIon
159.
S2 input – Switch ON value sent to 3rd association
group
Only in Double Smart Module
Description
This parameter defines value sent with Switch
ON command to devices in 3rd association
group when using S2 input.
Parameter size
2B
Default value
255
Available
values
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
160.
S2 input – Switch OFF value sent to 3rd association
group
Only in Double Smart Module
Description
This parameter defines value sent with Switch
OFF command to devices in 3rd association
group when using S2 input.
Parameter size
2B
Default value
0
Available
values
0 – turn off
1-99 – turn on and set level
255 – turn on with last level
161.
S2 input – Double Click value sent to 3rd association
group
Only in Double Smart Module
Description
This parameter defines value sent with Double
Click command to devices in 3rd association
group when using S2 input.
Parameter size
2B
Default value
99
Available
values
0 – turn off
1-99 – turn on and set level
255 – turn on with last level