IMPORTANT:
Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the
desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the
same logic applies: Values greater than 32768 may needed to be given as negative values too.
Parameter 1: Minimum brightness level
The parameter can be changed manually after the calibration.1-98 - percentage level of brightness
CAUTION: The maximum brightness level (parameter 2) must be greater than the minimumbrightness level (parameter 1).
Size: 1 Byte, Default Value: 1
Setting
Description
1 - 98
percentage level of brightness
Parameter 2: Maximum brightness level
The parameter can be changed manually after the calibration
Size: 1 Byte, Default Value: 99
Setting
Description
2 - 99
percentage level of brightness
Parameter 3: Incandescence level of dimmable compact fluorescent lamps
Virtual value set as a percentage level between parameters MIN (1%)and MAX. (99%). The Dimmer 2 will set to this value after first switchon. It is required for
warming up and switching dimmable compactfluorescent lamps and certain types of light sources.
Size: 1 Byte, Default Value: 1
Setting
Description
1 - 99
percentage level of brightness
Parameter 4: Incandescence time of dimmable compact fluorescent lamps
This parameter determines the time required for switching compactfluorescent lamps and certain types of light sources. Setting this parameterto 0 will disable the
incandescence functionality.
Size: 2 Byte, Default Value: 0
Setting
Description
0 - 255
0s - 25,5s
Parameter 5: Automatic control - dimming step size
This parameter defines the percentage value of dimming step during the automatic control.
Size: 1 Byte, Default Value: 1
Setting
Description
1 - 99
dimming step percentage value
Parameter 6: Time of a dimming step at automatic control
This parameter defines the time of single dimming step set in parameter 5 during the automatic control.
Size: 2 Byte, Default Value: 1
Setting
Description
0 - 255
(0s - 2,55s)
Parameter 7: Manual control - dimming step size
This parameter defines the percentage value of dimming step during the manual control.
Size: 1 Byte, Default Value: 1
Setting
Description
1 - 99
dimming step percentage value
Parameter 8: Manual control - time of a dimming step
This parameter defines the time of single dimming step set in parameter 7 during the manual control.
Size: 2 Byte, Default Value: 5
Setting
Description
0 - 255
0s - 2,55s
Parameter 9: Saving the state of the device after a power failure
The Dimmer 2 will return to the last state before power failure.
Size: 1 Byte, Default Value: 1