Setting
Description
0
leading edge
1
trailing edge
Parameter 32: On/Off mode
This mode is necessary while connecting non-dimmable light sources. Setting this parameter to 1 automatically ignores brightening/dimming time settings. Forced
auto-calibration will set this parameter-value to 2
Size: 1 Byte, Default Value: 2
Setting
Description
0
on/off mode disabled (dimming is possible)
1
on/off mode enabled (dimming is not possible)
2
mode selected automatically
Parameter 33: Dimmability of the load
This parameter contains an information about possibility of dimming the load detected during calibration procedure. (read oly)
Size: 1 Byte, Default Value: 0
Setting
Description
0
Load recognized as dimmable
0
no soft-start
Parameter 34: Soft-Start functionality
Time required to warm up the filament of halogen bulb.
Size: 1 Byte, Default Value: 1
Setting
Description
0
no soft-start
1
short soft-start (0,1s)
2
long soft-start (0,5s)
Parameter 35: Auto-calibration after power on
This parameter determines the trigger of auto-calibration procedure,e.g. power on, load error, etc.
Size: 1 Byte, Default Value: 1
Setting
Description
0
No auto-calibration of the load after power on
1
Auto-calibration performed after first power on
2
Auto-calibration performed after each power on
3
Auto-calibration performed after first power on or after each LOAD ERROR alarm
Parameter 37: Behaviour of the Dimmer after overload or surge.
Occuring of errors related to surge or overcurrent results in turning off the output to prevent possible malfunction. By default the device performs three attempts to
turn on the load (useful in case of momentary, short failures of the power supply
Size: 1 Byte, Default Value: 1
Setting
Description
0
device permanently disabled until re-enabling by command or external switch
1
three atempts to turn on the load
Parameter 39: Power limit - OVERLOAD
Reaching the defined value will result in turning off the load. Additionalapparent power limit of 350VA is active by default
NOTE: Parameter 39 is relevant only when parameter 58 is set to 0.
Size: 2 Byte, Default Value: 250
Setting
Description
0
functionality disabled
1 - 350
1W-350W
Parameter 40: Response to General Purpose Alarm
Size: 1 Byte, Default Value: 3