Installing your Alignment Plate:
Important Notice for Installer
To achieve proper aesthetic installation of the Acenti
products, the wall surface surrounding the wall box opening
must be fairly flat and free of irregularities. The wall box
must be level and recessed or flush to the wall surface. The
Acenti installation system allows for adjustments that will
correct minor flaws that may be present in the installation
area.
This device must be installed with the Acenti™ Alignment
Plate. The Alignment Plate is packaged with the Acenti™
Wallplate, which is sold separately from this device.
The Alignment Plate will function properly only if it is
mounted to a flat wall surface as described above.
• Leviton recommends to temporarily position the Alignment
Plate prior to wiring the device. If the wall box wires
extend at least 6 inches out of the wall box, it is also
possible to install the Alignment Plate after the device has
been wired (refer to Wallplate instruction sheet).
Single Pole (One location) or 3-Way (Multi-location)
Fluorescent Dimmer (Lighted)
Cat. No. ACX1Ø-1L, 1000VA
120VAC, 60Hz
For use with Mark 10™
Powerline and Tu-Wire
TM
dimmable ballasts
INSTALLATION INSTRUCTIONS
Installing your Dimmer –
Single-Pole Wiring Application:
DI-000-ACX10-00A-X0
Tools needed to install your Dimmer:
Slotted/Phillips Screwdriver
Electrical Tape
Pliers
Pencil
Cutters
Ruler
Installing Dimmer by itself or with other devices:
If installing Dimmer in a single device application, proceed with the
INSTALLING YOUR DIMMER section. If installing Dimmer in a multi-
device application, proceed as follows:
MULTI-DEVICE APPLICATION
In multi-dimmer installations, the reduction of the dimmer’s capacity
is required. Breaking off fins is not required on this device. Refer to
the chart for maximum load per dimmer.
WIRING DIMMER:
Connect wires per WIRING DIAGRAM as follows:
•
Green or bare copper wire in wall box to Green dimmer lead.
•
Line Hot wall box wire to Black dimmer lead.
•
Load wall box wire to Red dimmer lead.
•
Line Neutral wall box wire to White dimmer lead.
•
Yellow/Red wire should have Red insulation label affixed.
NOTE: If insulating label is not affixed to Yellow/Red dimmer
lead, use electrical tape to cover.
•
Proceed to Step 6.
WARNINGS AND CAUTIONS:
•
To be installed and/or used in accordance with appropriate electrical codes and regulations.
•
If you are unsure about any part of these instructions, consult a qualified electrician.
•
To avoid overheating and possible damage to this device and other equipment, use only with the appropriate Advance Transformer 120V Mark 10™
Powerline
or Lutron Tu-Wire™ electronic ballasts for controlling the specific fluorescent lamps.
•
When retrofitting Mark 10™
Powerline dimming ballasts into fixtures that originally had Instant Start ballasts, the sockets MUST be replaced with Rapid Start
sockets to allow proper dimmer operation and prevent damage to the dimmer ballast. Refer to the instructions provided with the ballast.
•
Acenti™ dimmers are not compatible with standard 3-way or 4-way switches. They must be used with compatible Acenti™ remotes for multi-location dimming.
•
Use only one (1) dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s) will
turn the light on at the brightness level selected at the dimmer.
WARNINGS AND CAUTIONS:
•
Lamps must be burned in at full intensity for 100 hours prior to dimming for proper dimming performance.
•
For new installations, wire a test switch before installing dimmer.
•
Total minimum load must exceed 40W.
•
Dimmer may feel warm to the touch during normal operation.
•
Recommended minimum wall box depth is 2-1/2".
•
Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft.
•
Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
•
Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
IMPORTANT: For 3-Way applications, note that one of the screw
terminals from the old switch being removed will usually be a different
color (Black) or labeled Common. Tag that wire with electrical tape
and identify as the common (Line or Load) in both the dimmer wall
box and remote wall box.
For non-standard wiring applications, refer
to Wire Nut and Conductor Size Chart
MAXIMUM BULB WATTAGE:
Mark 10™
Powerline dimmers are rated in Volt-Amps (VA). The
maximum bulb wattage is determined by the efficiency of the Mark
10™
Powerline ballast. The following table shows the maximum
number of ballasts that can be connected to a single dimmer for
different Mark 10™
Powerline ballasts. Also note that the table shows
maximum ballasts for multi-gang installations.
Preparing and connecting wires:
Pull off pre-cut insulation from dimmer leads. Make sure that
the ends of the wires from the wall box are straight (cut if
necessary). Remove insulation from each wire in the wall
box as shown.
CFM26W/GX24Q
CFM32W/GX24Q
CFM42W/GX24Q
CFQ26W/24Q
F25T8
F25T8
F25T8
F32T8
F32T8
F32T8
FT40W/2G11
FT40W/2G11
Cat. No. ACX1Ø-1, 120V, For use with
Advance Transformer 120V Mark 10™
Powerline Electronic Ballasts
Lamp
Max. # Ballasts/
Dimmer for Multi-gang
Two
Ganged
32
26
20
17
32
17
11
28
14
9
25
12
26
21
16
14
26
13
9
22
11
8
20
10
More than
2 Gang
22
18
14
12
22
12
8
19
10
7
17
9
Single
Gang
REZ-1T32
REZ-1T32
REZ-1T42
REZ-2Q26
REZ-132
REZ-2S32
REZ-3S32
REZ-132
REZ-2S32
REZ-3S32
REZ-1TTS40
REZ-2TTS40
Advance
Mark 10™
Powerline
Part No.
Lutron Tu-Wire™:
To determine total ballast load, add the line current found on the
ballast label for all ballasts in the circuit. This will indicate the total
load for the control.
Step 1
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH;
TURN OFF POWER at circuit breaker or fuse and test
that power is off before wiring!
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
Identifying your wiring application (most
common):
NOTE: If the wiring in the wall box does not resemble
any of these configurations, consult a qualified electrician.
Step 2
2
4
3
1
2
4
1
5
3
3-Way
1. Line or Load
(See important
instruction below)
2. Neutral
3. Ground
4. First Traveler – note color
5. Second Traveler – note color
NOTE: For matching remote w/LEDs
installation, the First Traveler becomes
Line Hot.
Single-Pole
1. Line (Hot)
2. Neutral
3. Ground
4. Load
Step 3
Cut
(if necessary)
Strip Gage
(measure bare
wire here)
1 - #12 w/ 1 to 3 #14, #16 or #18
2 - #12 w/ 1 or 2 #16 or #18
1 - #14 w/ 1 to 4 #16 or #18
2 - #14 w/ 1 to 3 #16 or #18
WIRE NUT / # OF COND.
COMBINATION CHART
Primary
Side
Hot (Black)
Neutral (White)
Ballast
Dimmer
Black
Insulating
Label
White
Black
White
Red
Green
Ground
Line
120VAC, 60Hz
Yellow/Red
INSTALLING YOUR DIMMER
NOTE: Use check boxes when Steps are completed.
√
5/8"
(1.6 cm)
Step 4
Step 4 cont'd
Alignment Plate
Held By Tape
Alignment Plate Held
By Mounting Screw
•
For Single-Pole Application, go to Step 5a.
•
For 3-Way Coordinating Remote (no LEDs) Application, go to Step 5b.
•
For 3-Way Matching Remote (with LEDs) Application, go to Step 5c.
TOP
Mounting
Screw
Alignment
Plate
TOP
Electrical
Tape
• The Alignment Plate must be installed with the tab towards
the bottom.
• Leviton recommends the following 3 methods to
temporarily hold the Alignment Plate – use of device
mounting screw, use of wall box wires, or use of electrical
tape (refer to the following figures):
Alignment Plate
Held By Wires
TOP
Step 5a
A
C
B
ACX1Ø 1000VA (8.3A) 800VA (6.6A) 650VA (5.4A)
More than
Cat. No.
Single
Two Devices 2 Devices
MAXIMUM LOAD PER DIMMER FOR MULTI-DEVICE
Insulating label:
This wire is used in 3-way installations only.
For single pole installations, do not remove
this insulating label.
1
4
2
3
Black
White
Green
Red
Yellow/Red