Equipment Details
63
5. Any modifications to the appliance or the
use of spare parts and accessories
important for operation which are not
original Truma parts, or non-observance
of the instructions for installation and use
will result in the guarantee becoming
invalid and no liability will be assumed.
Furthermore the approval for operating
the appliance will become invalid and in
some countries also the approval for
operating the vehicle.
TECHNICAL DATA
Power supply:
230 V ~, 50 Hz
Power consumption at power setting:
500 W: 2.2 A
1000 W: 4.5 A
2000 W: 8.5 A
Weight:
approx 2kg
The mains element on the space heater
is designed for supplementary heating.
It is not recommended to run alongside
the gas for prolonged periods of time.
TEB FAN
Always observe the operating instructions
prior to starting!
The vehicle owner is responsible for the
correct operation of the appliance.
Repairs are only to be carried out by an
expert!
a = Manual control
(e.g. for ventilation) Adjust desired output
at the control knob.
b = Off
(or automatic operation/ heating with
heaters Trumatic S 3002 K and S 5002 K)
c = Automatic operation
(Heating) The output steadily adjusts to
the respective heat emission of the
heater. The maximum output can be
limited at the control knob, as required.
The regulating between this value and
slow running is carried out automatically.
The quantity of air can be individually
adjusted at the air flap (f), for warm air
distribution.
In centre position 50% of the warm air is
distributed to each outlet.
Use the fan duct with 72 mm and if the fan
ducts are of different lengths or on sides
with a greater heat requirement. This means
that the air output can be used to the full on
this side. By adjusting the air flap (f) the
quantity of air can be increased individually.
This means that the air out-put on the other
side is reduced.
If the air output drops or the operating noise
increases, the fan impeller wheel may be
severely soiled.
a
b
c
Summary of Contents for X2-50 Cab
Page 8: ...THE MOTORHOME CODE Code of Conduct 12 The Country Code 14 The Coastal Code 14 ...
Page 19: ... EN ROUTE Spare Wheel Removal 24 ...
Page 21: ...ARRIVAL AT SITE Positioning the Motorhome 30 ...
Page 27: ...Connecting Services 35 Typical gas schematic drawing ...
Page 119: ...SAFETY SECURITY Fire 26 Ventilation 26 Escape Paths 26 Children 26 Security 26 ...