Description & Features 

CBS-2140XTS Series coffee brewers feature universal spray over technology from the Cascading Spray Dome™. 

 

The following variables are programmed for each batch size: 

™

 

Brew volume 

™

 

Prewet percent (Percentage of the brew volume) 

™

 

Brew time 

™

 

Prewet delay (The time between prewetting and the brew cycle) 

™

 

Adjustable number of pulses  

™

 

Bypass-infinitely variable for strength adjustment 

™

 

Drip delay 

(The time between the end of the brew cycle and end of the brewing cycle…to empty the brewbasket)

 

 

Operating Principles 

Using these variables, the software calculates how much water to use for prewetting and brewing.  The total brew time 
digitally divides into several cycles. Within these cycles, the software calculates how long to spray water over the coffee 
grounds, and how long to pause before the next cycle begins.  If desired, pulse count and length, brew-volume may be 
adjusted without changing brew time and brew-time may be adjusted without changing volume brewed. 

 

Factory settings 

 

The following are the factory set defaults—all variables in the brew menu are adjustable: 
Brew Volume and coffee filter size:

 

CBS-2140 single and Twin: 

1 gallon/3.8 liters per brew 

Coffee Filters: 13” X 5”  FETCO Product #F002 

Brew Time, all models: Factory set at 5.5 minutes=

[

4 minute brew time + 1.5 minute drip delay

]  

Temperature Control:

 

Water temperature is factory set at —93°C/200°F  

 

Features 

 
 
 

™

 

Touchscreen  Operation 

[

XTS

: E

X

tractor 

T

ouch 

S

creen]

 

™

 

Brew water low temperature lockout 

™

 

Cascading Spray Dome-No clog sprayhead 

™

 

ECO mode for tank heater energy savings  

™

 

Brew mechanism is digitally adjustable 

™

 

Dispenser locator under brew basket 

™

 

Intuitive Control Settings for Batch sizing 

™

 

Magnetic flux brew basket sensor 

™

 

Infinitely variable bypass for strength adjustment 

™

 

Brewbasket locks (configurable) 

™

 

Four fully programmable batch sizes per side 

™

 

Totalizing counters for brewer functions  

™

 

User programs save-to and load-from SD cards 

™

 

Optional gourmet stainless steel brewbasket 

™

 

Recipe copy to SD card 

™

 

Demonstration Mode for review & training 

™

 

Customizable batch name 

™

 

Heavier gauge stainless steel cabinet 

™

 

Screen logo customizable by user from SD card 

™

 

Configurable for FLOWJET® pump module 

™

 

SD card firmware program and upgrade installation  

™

 

SD card Backup for menu items 

™

 

Dedicated Electrical Connection-not user selectable 

™

 

Excellent value for gourmet coffee service 

 

Summary of Contents for CBS-2141XTS

Page 1: ...tures Batch Parameters 7 How to calibrate the flow rate 10 Operator Training 12 Service Guide to a Successful Installation 13 Installation Directions 14 CBS 2140XTS Dimensions Utility Connections 18 E...

Page 2: ...hanging volume brewed Factory settings The following are the factory set defaults all variables in the brew menu are adjustable Brew Volume and coffee filter size CBS 2140 single and Twin 1 gallon 3 8...

Page 3: ...screen will briefly illuminate Turn main power switch to ON Switch located lower right side of back panel When Complete the HOME SCREEN will display Immediately touch and hold finger to enter programm...

Page 4: ...wer rails Brewbasket s must be in place Have empty dispenser under brewbasket Use the convenient locator guide Tap READY screen to enter the batch selection menu A long duration TAP with fingertip Tou...

Page 5: ...2142XTS brewing simaltanously Left side completing drip delay Brew basket sensor enabled Unit is brewable only when brebasket is in place option may be disabled by user CBS 2142XTS dual side right si...

Page 6: ...gramming items shown below Programming category screens Menu Tree Programming category screens To enter Turn unit OFF After 10 second delay turn unit ON Home Screen will appear Immediately place finge...

Page 7: ...ON _________ ________ ON OFF Batch Summary Display Summary Batch Name Regular 1 Regular 1 16 Write own name Batch Volume 1 50 gal 0 50 2 00 1 00 gal _________ ________ 0 50 2 00 Brew Time 4 00 mm ss...

Page 8: ...perature ft m Suggested Setting F Boiling point F Suggested Setting C Boiling point C 0 0 200 212 0 93 100 0 500 152 200 211 0 93 99 5 1000 305 200 210 1 93 98 9 2000 610 200 208 1 93 97 8 2500 762 20...

Page 9: ...ress to test TEST Press To Test Runs Valve to verify flow Have container under brewbasket R Valve Calib Calibrate Flow Rate 1540 ml p m _________ ________ 1400 1900 Factory or service use for flow rat...

Page 10: ...the number 2 AUTOMATIC Built in CALIBRATE THE FLOW RATE Enter this number in milliliters into the calibration slider for the Valve tested in the OUTPUT MENU Use milliliters If measured in fluid ounce...

Page 11: ...tivated Right Brew gal Right Bypass activated Right Bypass gal Fill valve Activated Fill Valve gal Heater Activated Heater ON time Touch To Return 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 00 Identical screen for...

Page 12: ...cloth and hot suds on the outside to avoid scratches Never use abrasives that will scratch surface Weekly 1 Use a commercial coffee dispenser cleaner such as URNEX TABZ DIP IT or Squeak n Clean 2 Car...

Page 13: ...nd waste piping and connections shall comply with the International Plumbing Code 2003 International Code Council ICC or to the Uniform Plumbing Code 2003 IAPMO 3 Use an inline water filter for all be...

Page 14: ...the unit and verify that it will fit properly in the space intended for it Verify that the counter or table will support the total weight of the brewer and dispensers when filled See Technical Data 1...

Page 15: ...le on the lower back 5 A fused disconnect switch or circuit breaker on the incoming power line must be conveniently located near the brewer and its location and markings known to the operators 6 The t...

Page 16: ...16...

Page 17: ...E EXPORT Japan CBS_2142XTS Twin 1 gallon version Electrical Configurations Configuration Codes Plastic Brewbasket Stainless Steel Brewbasket Heater Configuration Voltage Phase Wires Electrical Connect...

Page 18: ...b 18 6 kg 16 x 23 x 29 406 x584x737mm CBS 2142XTS Dual 1 gallon 34 873mm 19 502mm 20 518mm 47lb 21 3kg 92lb 41 7kg 114 4lb 51 9 kg 5 8 gal 22 1 l 58lb 26 3kg 23 x 25 x 29 584x635x737mm Rough in CBS 21...

Page 19: ...ve Check inside of machine for leaks 107 Fault Lower liquid level probe Tank not filling Occurs during prefill low probe is uncovered 201 Heater open high limit thermostat or Solid State Relay SSR fau...

Page 20: ...will be displayed P 8 After the water has reached the set temperature Screen 3 will display READY 9 Review the Operating Instructions Brew one full batch water only on each side to confirm proper fill...

Page 21: ...1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 1 5 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 4 CBS 2142 XTS Back Panel CE Drawings 1109 00047 00 SERVICE PARTS ITEM NO PART NO DESCRIPTION QTY...

Page 22: ...00 ASSEMBLY BYPASS VALVE LEFT 1 9 1001 00181 00 COVER FRONT CBS 2100 XTS 2 10 1402 00051 00 HARNESS LOW AMP CBS 2142 52 XTS CE UL 1 11 1402 00060 00 HARNESS HIGH AMP CBS 2142 XTS UL 1 12 1057 00043 0...

Page 23: ...003 00140 00 ALUMINUM BRACKET FOR SSR 2 6 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 2 7 1081 00042 00 STANDOFF 1 4 HEX 4 8 1112 00019 00 PROBE WELDMENT WATER LEVEL 2 600 LG 1 9 11...

Page 24: ...1 10 1073 00002 00 LEG FLANGE FOOT 4 0 HIGH 4 11 1057 00043 00 SOLENOID VALVE SINGLE 180 DEG 24VDC 1 12 1102 00243 00 ADAPTER ASSY 3 4 BSP x 1 4 NPT x 3 8 TUBE 1 13 1023 00147 00 PLUG TANK SERVICE DRA...

Page 25: ...SHOT THERMOSTAT 2 4 1053 00003 00 THERMOSTAT SINGLE SHOT 240V 40A 2 5 1003 00140 00 ALUMINUM BRACKET FOR SSR 2 6 1052 00033 00 RELAY SOLID STATE 50A 480VAC W BUILD IN VARISTOR 2 7 1081 00042 00 STANDO...

Page 26: ...250VAC 1 4 1052 00001 00 POWER SUPPLY 90 264VAC 24VDC 1 8A 1 5 1029 00012 00 SPACER 25 HEX X 1 LG FEM 4 40 THREAD 4 CBS 2141 XTS Back Panel CE Drawings 1109 00046 00 SERVICE PARTS ITEM NO PART NO DES...

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ......

Page 33: ......

Page 34: ......

Reviews: