3
Weights Capacities and Measurements
Weights and Capacities & Measurements; 3 liter and 1 gallon brewers
Brewer Height Width Depth
Empty
Weight
Filled
Weight
Total Weight-
Brewer &
Filled Dispenser
Shipping
Weight
Shipping Dimensions
CBS-2131
3 liter
21
⅜
”
54.3cm
11 ¾”
30.3cm
20
⅜
”
51.8cm
29 lb
13.1kg
50 lb
22.7 kg
61.2lb
27.8 kg
36.3 lb
16.5 kg
22 ¾”x 16 5/8” x 22 7/8”
57.8 x42.3x58.1cm
CBS-2131
I gallon
23
⅜
”
59.4cm
11 ¾”
30.3cm
20
⅜
”
51.8cm
29 lb
13.1kg
50 lb
22.7 kg
63lb
28.6 kg
36.3 lb
16.5 kg
22 ¾”x 16 5/8” x 22 7/8”
57.8 x42.3x58.1cm
CBS-2132
3 liter
21
⅜
”
54.3cm
19 ¾”
50.2cm
20
⅜
”
51.8cm
42.6lb
19.3 kg
87.6 lb
39.7kg
110lb
49.9 kg
49.4 lb
22.4 kg
24½” x 22
⅞
” x 23”
62.2 x 58.1 x 58.4cm
CBS-2132
I gallon
23
⅜
”
59.4cm
19 ¾”
50.2cm
20
⅜
”
51.8cm
42.6lb
19.3 kg
87.6 lb
39.7 kg
114 lb
51.7 kg
49.4 lb
22.4 kg
24½” x 22
⅞
” x 23”
62.2 x 58.1 x 58.4cm
Electrical Configuration and Brewing Efficiency
.
Electrical Configurations-
CBS-2132—3 liter version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Gallon/Hour
(3 liters per batch)
E213201
2 X 2.3 kW
NO
200-240
1
2+G
Terminal Block 3.3 – 4.7 16.5 - 19.7
11.5 gal/43.5 lit
E213202
2 X 3.0 kW
NO
200-240
1
2+G
Terminal Block 4.2 – 6.1 21.3—25.5
14.0 gal/53 lit
.
Electrical Configurations-
CBS-2131—1 gallon airpot version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Gallon/Hour
(1 gallon per batch)
E213102
1 X 2.3 kW
NO
100 - 120
1
2+G
NEMA 5-20P
1.7 – 2.4
16.5 - 19.7
5.8 gal/22 lit
E213112
1 X 2.3 kW
YES
100 - 120
1
2+G
NEMA 5-20P 1.7 – 2.4
16.5 - 19.7
5.8 gal/22 lit
E213106
1 X 2.3 kW
NO
200 - 240
1
2+G
Cord/No Plug 1.7 – 2.4
8.5 – 10.1
5.8 gal/22 lit
E213116
1 X 2.3 kW
YES
200 - 240
1
2+G
Cord/No Plug 1.7 – 2.4
8.5 – 10.1
5.8 gal/22 lit
E213108
1 X 3.0 kW
NO
200 - 240
1
2+G
Cord/No Plug 2.2 – 3.1
10.9 – 13.0
7.7 gal/29.1 lit
E213118
1 X 3.0 kW
YES
200 - 240
1
2+G
Cord/No Plug 2.2 – 3.1
10.9 – 13.0
7.7 gal/29.1 lit
.
Electrical Configurations-
CBS-2132—1 gallon airpot version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum
Amp Draw
Gallon/Hour
(1 gallon per batch)
E213203
2 X 3.0 kW
NO
200-240
1
2+G
Terminal Block 4.2 – 6.1 21.3—25.5
14.0 gal/53 lit
E213213
2 X 3.0 kW
YES
200-240
1
2+G
Terminal Block 4.2 – 6.1 21.3—25.5
14.0 gal/53 lit
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice
Electrical Configurations-
CBS-2131—3 liter version
Configuration
Code
Heater
Configuration
Bypass
Voltage
Phase
Wires
Electrical
Connection
KW
Maximum Amp
Draw
Gallon/Hour
(3 liters per batch)
E213103
1 X 1.5 kW
NO
100 - 120
1
2+G
NEMA 5-15P
1.1 – 1.6
10.9 – 13.0
3.9 gal/14.8 lit
E213104
1 X 1.7 kW
NO
100 - 120
1
2+G
NEMA 5-15P
1.3 – 1.8
12.3 - 14.7
4.4 gal/16.7 lit
E213101
1 X 2.3 kW
NO
100 - 120
1
2+G
NEMA 5-20P
1.7 – 2.4
16.5 - 19.7
5.8 gal/22 lit
E213105
1 X 2.3 kW
NO
200 - 240
1
2+G
Cord/No Plug
1.7 – 2.4
8.5 – 10.1
5.8 gal/22 lit
E21310
7
1 X 3.0 kW NO
200 - 240
1 2+G Cord/No Plug 2.2 – 3.1 10.9 – 13.0 7.7 gal/29.1 lit