![Fetco CBS-2131 XTS User Manual Download Page 17](http://html.mh-extra.com/html/fetco/cbs-2131-xts/cbs-2131-xts_user-manual_2285210017.webp)
17
Hot water convenience tap
1. The CBS-2130 coffee brewers include a hot water convenience tap for single cup beverage purposes.
2. Single use delivery volume should not exceed maximum 16fl.oz/473cc.
3. Water dispensed from this faucet is very hot, up to 205°F/96°C
Adjustable spray pattern
This FETCO equipment features digitally adjustable spray patterns for perfect penetration
FETCO CBS-2131 and CBS-2132 coffee brewers feature digitally adjustable spray patterns for perfect penetration.
All batches can be set for wide, middle or narrow spray patterns of the hot brew water that showers the coffee bed
in the brewbasket. The turbulence created by the spray pattern combined with variable pulses is infinitely
adjustable for desired flavor extraction of individual roasts and grinds of any coffee variety.
The default setting for all batches is WIDE. The brewer software calculates and corrects to achieve proper volume
based on the flow rate changes of the spray pattern.
Error Codes
Code Description
Possible Cause
Corrective Action
How to Clear
Error Codes
050 Shorted temperature probe Probe failure.
Replace probe.
051 Open temperature probe.
Bad probe
connection, or
probe failure.
Check all connections.
Replace probe if necessary.
100
Initial Fill Error. Initial fill
time was more than 4
minutes after power up.
Water supply flow
rate is too low.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter...)
101
Error on refill
Tank did not refill within 3
minutes.
Water supply flow
rate is too low.
Watch for short potting
during brew cycle.
Investigate cause of low flow
rate. (Clogged water filter…)
102 Unwanted
fill;
Possible leak in
tank, fitting, or
valve.
Check inside of machine for
leaks.
103 Liquid level probe fault
Probe fouled or
shorts
Clean, check all
connections. Replace probe
if necessary.
201
Heater open, high limit
thermostat, or Solid State
Relay (SSR) fault
SSR, High Limit,
or heating
element failure.
Check and replace heating
elements if necessary.
INSERT
BREW
BASKET
Brewbasket must
be in place
Insert brewbasket
CLEAR FAULT, make
repairs as required
Below is the only way to
clear error codes
1) Enter
“PROGRAMMING”
2)Scroll left to “OTHER”
3)Scroll down to
“ERROR CODES”
4)Scroll down to “Display
Errors”
5)Scroll left to “Reset
Errors”
6)Scroll down to “Reset”
7)Follow directions
shown on screen.
Toggling ON/OFF switch
will not clear error codes.
Error codes must be
cleared!
Designs, materials, specifications, physical dimensions, firmware and software protocol for equipment or replacement parts are subject to review and change by FETCO without notice