MS6-SV-...-D-10V24
Festo – MS6-SV-...-D-10V24 – 1702a English
13
5.3
Switching logic
In the normal position (completely exhausted MS6-SV-D), the pilot valves V1 and V2 are not actuated.
If both pilot valves are actuated, the MS6-SV-D switches first to the switching position 1 and then,
when the switch-through pressure is reached, automatically into switching position 2 (
è
Fig. 4).
V1
V2
S1
S2
S3
MS6-SV-D
Voltage [V]
Switching
position
Status
0
0
1
1
1
Normal position
Connection 1 closed,
passage from connection 2 to 3 opened
24
0
0
1
1
Normal position, optional testing condition
(
è
Tab. 6)
Port 1 closed,
passage from port 2 to 3 opened
0
24
1
0
1
Normal position, optional testing condition
(
è
Tab. 6)
Reduced flow via flow control valve from port 1 to 2,
passage from port 2 to 3 opened
24
24
0
0
1
Switching position 1
Reduced flow via flow control valve from port 1 to 2,
passage from port 2 to 3 closed
24
24
0
0
0
Switching position 2
Full flow from port 1 to 2;
passage from port 2 to 3 closed
Tab. 3
Switching logic
5.4
Function
Symbol
Function
Soft-start/quick exhaust valve, electrically
actuated.
Tab. 4
Circuit symbol for the function