MS6-SV-...-D-10V24
Festo – MS6-SV-...-D-10V24 – 1702a English
27
MS6-SV-D
Valve function
3/2-way valve, monostable, closed
Pressure build-up function
Assembly position
Any
Operating medium
Compressed air in accordance with ISO 8573-1 [7:4:4]
lubricated operation possible (in which case lubricated
operation will always be required)
Ambient temperature
[°C]
–10 … +50
Temperature of medium
[°C]
–10 … +50
Storage temperature
[°C]
–10 … +50
Shock resistance
Shock test with severity level 2 according to
EN 60068-2-27
Vibration resistance
Transport use check with severity level 2 in accordance
with EN 60068-2-6
Operating pressure
[bar]
3.5 …10
C value
[l/(s bar)] 19.3
b value
0.21
Standard nominal flow rate
1
>
2
[l/min.]
4300 (if p1 = 6 bar, p2 = 5 bar)
Standard flow rate 2
>
3
[l/min]
9000 (at p1 = 6 bar)
Min. standard flow rate 2
>
3
in the event of the most critical
error
[l/min]
6000 (at p1 = 6 bar)
Min. bleeding of the silencer
UOS-1
[l/min]
24,000 (at p1 = 6 bar)
Residual pressure in normal
condition
[bar]
0 (no residual pressure)
Max. residual pressure for
a worst-case error
1)
[bar]
0.4 (if p1 = 10 bar and flow control valve is fully open)
Switch-through pressure
Approx. 50 % of p1
è
Fig. 5
Filling flow
Adjustable by means of flow control valve
è
Fig. 10
Min. pause after bleeding off
[s]
1
Noise level
[dB(A)]
75 with silencer UOS-1
Housing material
Die-cast aluminium
Seal material
Nitrile rubber
Weight
[g]
2110 with silencer UOS-1
1)
The indicated value was determined using the silencer UOS-1. Depending on the level of contamination of the silencer the residual
pressure can be higher. It is the task of the user/operator to determine how probable additional hazards are, and whether addition
al measures are required.
Tab. 13
General data