ZSB−1/8
Festo ZSB−1/8 0701NH English
20
9
Ca
re
a
n
d
ma
inten
a
n
c
e
Maintenance
S
Check every month to be sure that the product is functioning correctly by
applying a pressure of 2.8 bar with switched pressure sequence valve as
described in chapter 7.
Cleaning
1. Exhaust the complete system and the product.
2. Unscrew the filter element
5
. Do not lose the seals when doing this.
3. Clean the components of the product exclusively with the cleaning agents
specified as per Fig.7.
C
o
m
ponent
C
le
a
nin
g
ag
ent
C
le
a
nin
g
interv
a
l
Housing
Water (max. +60 °C)
if required
Screw with filter
element
5
Silencers
Compressed air
Water (max. +60 °C)
Petroleum ether
half yearly or
after every 100000
switching cycles
Fig.7
4. Screw in again the screw with filter element
5
, max. tightening torque 4Nm.
10
Acc
e
ss
orie
s
D
e
s
i
g
n
a
tion
T
ype
Service units
MSB..., LFR−...−D−...
Front panel valve
SV−3−M5
Pushbutton actuator
T−22−SW, T−30−SW
Mushroom pushbutton
P−22−SW, P−30−SW
Silencers
U−
x
Pressure sequence valve
VD−3−PK−3
Fig.8