ZSB−1/8
Festo ZSB−1/8 0701NH English
17
S
Use the product in its original state.
Unauthorized modification is not permitted.
The individual components are fixed with
screw locking agent (Fig.4).
5
Fittin
g
Me
c
h
a
ni
ca
l in
s
t
a
ll
a
tion
1. Place the product so that filter
4
for the breathing opening is not covered.
2. Fasten the product with two M5 x nn screws in the through holes
6
or with
two M6 x nn screws via the fastening thread.
3. Install two 3/2−way push−button valves as per Fig.3.
Wa
rnin
g
Any attempt to actuate the push−button
valves with only one hand or with an elbow,
a knee or a foot will impede the safety
function (Fig.5).
S
Make sure that the specifications
required for setting up two−hand
push−button switching circuits as per
DINEN574 and DINEN954−1 are
observed.
S
If necessary, take into account existing
C−standards for your type of machine.
S
Implement the measures as per
DINEN574.
Fig.4
ÔÔÔÔ
ÔÔÔÔ
ÔÔÔÔ
ÔÔÔÔ
ÔÔÔÔ
ÔÔÔÔ
ÔÔÔÔ
ÔÔÔÔ
Fig.5
ÔÔ
Ô